[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX0M2 / prf-solomatov-pred-sony-dsc-rx0m2-596bf48fc26d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX0M2 / prf-solomatov-pred-sony-dsc-rx0m2-596bf48fc26d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2776343 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2776343; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.013353724665864411,
        0.021090367436588348,
        0.01779464208853157,
        0.000845877580687977,
        0.0006438290225667362,
        0.0004592166745967627,
        0.000011015920583299687,
        0.01793760605227812,
        0.050936757453960126,
        0.05652584713055987,
        0.0554706785148665,
        0.05822155619820749,
        0.05630118828977544,
        0.03332854045771722,
        0.004844360369017806,
        0.0015671384263399731,
        0.05779287357505899,
        0.30980858633101166,
        0.6187600739533984,
        0.7432733635577449,
        0.714910009318013,
        0.6421498712514988,
        0.5503820673454253,
        0.4734166131490237,
        0.4024463836060602,
        0.32545375337269206,
        0.25394460986989,
        0.17092890900007673,
        0.09698728867434607,
        0.04180774853827499,
        0.026911363977721772
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX0M2 / prf-solomatov-pred-sony-dsc-rx0m2-596bf48fc26d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX0M2 / prf-solomatov-pred-sony-dsc-rx0m2-596bf48fc26d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2776343 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2776343; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017803496902219933,
        0.02775272723867332,
        0.05102882821034721,
        0.0812690686993646,
        0.11138343497183165,
        0.1372268988377877,
        0.18420685052243185,
        0.2802873420178991,
        0.4036932396321348,
        0.5310583742714787,
        0.6760225231536593,
        0.8437244605583676,
        0.9582018504197788,
        1,
        0.9784728327875915,
        0.9159665070202061,
        0.819725228475012,
        0.6942493776885637,
        0.5600045455478664,
        0.4184659100118393,
        0.29651847772411405,
        0.19760813775531336,
        0.14241648096074583,
        0.10703658733809186,
        0.08349827092689915,
        0.05786514850650658,
        0.04967297268385066,
        0.030489038998423465,
        0.018004929506188535,
        0.012936428964288635,
        0.006726135063282887
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX0M2 / prf-solomatov-pred-sony-dsc-rx0m2-596bf48fc26d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX0M2 / prf-solomatov-pred-sony-dsc-rx0m2-596bf48fc26d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2776343 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2776343; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04335975418022917,
        0.10899428492805104,
        0.26117680704437457,
        0.4471238964349866,
        0.5662546018269357,
        0.6371285896591308,
        0.6841289782998714,
        0.6682274128232715,
        0.5982806879409353,
        0.4927343271346516,
        0.36345646053099345,
        0.2471750428531345,
        0.1569110012703762,
        0.10543170278312154,
        0.09425962858335588,
        0.09271123560741594,
        0.09866882442119003,
        0.08806861039864311,
        0.0646003069505461,
        0.0512115613956921,
        0.04594411425389442,
        0.03937832609299355,
        0.02687456845209688,
        0.007691954488332314,
        0.00003051462661493915,
        0.00006516193424227482,
        0.000016401258778184107,
        0.000008852716685222252,
        0.000023563323047620556,
        0.0000350362581280483,
        0.00015140236635026723
      ],
      "range": 1
    }
  }
]
