    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 5100 / prf-solomatov-pred-sony-ilce-5100-3a4ebeba3368@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 5100 / prf-solomatov-pred-sony-ilce-5100-3a4ebeba3368@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27872625 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27872625; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01036411532821182,
        0.019084250227597868,
        0.024041694314762243,
        0.0026999285140886444,
        0.016753235836237168,
        0.03207882285934676,
        0.04392996712724402,
        0.05358001264681744,
        0.06751239612343653,
        0.05721045290854378,
        0.043690639112749514,
        0.035013702512770147,
        0.04028924796283091,
        0.042435439790834195,
        0.04450097541943036,
        0.06228661993622775,
        0.11242427292011427,
        0.2604046443418946,
        0.4613985586215866,
        0.5741098658630107,
        0.5580321910835452,
        0.5063657979827878,
        0.4319897964400554,
        0.3648331866840672,
        0.3005699499060458,
        0.2355751422766962,
        0.1779657136706715,
        0.11675742776290356,
        0.06762173996887627,
        0.027542761401195617,
        0.015170754817675047
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 5100 / prf-solomatov-pred-sony-ilce-5100-3a4ebeba3368@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 5100 / prf-solomatov-pred-sony-ilce-5100-3a4ebeba3368@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27872625 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27872625; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015496499881155793,
        0.02694648961122248,
        0.05701882402536539,
        0.09680238944125284,
        0.13858748503235702,
        0.16655374942259654,
        0.21050009821464608,
        0.2947967764069584,
        0.3990153062368543,
        0.5126926868208501,
        0.6588125086890811,
        0.8332117983146546,
        0.9563229154053485,
        1,
        0.9804520743919886,
        0.9132028289405825,
        0.8114647256941174,
        0.6708403316874532,
        0.5184475089805858,
        0.3692361806611325,
        0.24384255160753604,
        0.14942492858135895,
        0.0985595795157435,
        0.0685971809257291,
        0.04780763562814769,
        0.03291452814365349,
        0.030908787744247268,
        0.017064000968692396,
        0.008295578547051095,
        0.007452089639924477,
        0.0016222716733712737
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 5100 / prf-solomatov-pred-sony-ilce-5100-3a4ebeba3368@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 5100 / prf-solomatov-pred-sony-ilce-5100-3a4ebeba3368@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27872625 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27872625; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04846161421825178,
        0.11441195079401383,
        0.27092751400343523,
        0.45542348451213327,
        0.5937836138505074,
        0.6957928074589315,
        0.7844250406985348,
        0.8246314080571887,
        0.812018745991811,
        0.7064403514200761,
        0.5445416784389701,
        0.36489613016355654,
        0.20002193908898067,
        0.08253911857960992,
        0.040128947309412015,
        0.018963025549262044,
        0.02791746561366215,
        0.033715683399034,
        0.027156496024324944,
        0.02070828779133648,
        0.02827995927904171,
        0.030932231894197266,
        0.028055129360797557,
        0.009627539566151377,
        0.000007548503235701696,
        0.00007201145209681543,
        0.000009135880097407402,
        0.000013119254106852153,
        0.000024211503581022598,
        0.00004063106004547473,
        0.001520722214000296
      ],
      "range": 1
    }
  }
]