[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM5 / prf-solomatov-pred-sony-ilce-7rm5-3242e7399569@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM5 / prf-solomatov-pred-sony-ilce-7rm5-3242e7399569@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28040332 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28040332; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.009770860416345997,
        0.020269148739037752,
        0.02534299665210811,
        0.0009223665754028874,
        0.01785841373062202,
        0.032096042942715515,
        0.046959194349054066,
        0.05825834729774241,
        0.07690538756816431,
        0.0735160874700057,
        0.06640868588859788,
        0.06223507981289237,
        0.06656650142373492,
        0.06585852121865034,
        0.05913064795381167,
        0.07555291428075815,
        0.12932925687185157,
        0.28997245824336176,
        0.5009381130009445,
        0.5982743000332521,
        0.5734414271557127,
        0.5167601439241162,
        0.4357753681375812,
        0.35929234361419116,
        0.28677256745747515,
        0.21763148168145796,
        0.15967505306285246,
        0.10290844987142092,
        0.056665705669961396,
        0.023205174603496134,
        0.008342355932162288
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM5 / prf-solomatov-pred-sony-ilce-7rm5-3242e7399569@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM5 / prf-solomatov-pred-sony-ilce-7rm5-3242e7399569@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28040332 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28040332; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015881067314038936,
        0.02654677341195532,
        0.05210676178869779,
        0.08326802621309905,
        0.11489924584345149,
        0.1414340600532119,
        0.18572295791647545,
        0.2771827737275008,
        0.38958957404641287,
        0.5029810274714294,
        0.6493983024166761,
        0.8245602441511748,
        0.9507020102329743,
        1,
        0.9827250618858578,
        0.9205180951495153,
        0.8194949332268961,
        0.6794428111621503,
        0.5266481152933568,
        0.3726043043998195,
        0.23757479048393576,
        0.139731501752547,
        0.09029510420917983,
        0.06439474040464285,
        0.04759820960750393,
        0.033102104497193544,
        0.03411504186184386,
        0.019035014991976556,
        0.008672614860622905,
        0.008863489918735626,
        0.00013450342171412235
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM5 / prf-solomatov-pred-sony-ilce-7rm5-3242e7399569@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM5 / prf-solomatov-pred-sony-ilce-7rm5-3242e7399569@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28040332 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28040332; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04492257973265081,
        0.10978006251851796,
        0.26241789861831877,
        0.4461650454067377,
        0.577036677026506,
        0.6719655815772795,
        0.7528480047953783,
        0.785400829062937,
        0.7749794117986905,
        0.687535511348439,
        0.5432307648853801,
        0.3853815639558048,
        0.23332558972554246,
        0.12430660236119885,
        0.07892900483489282,
        0.051385311700303686,
        0.0511844260617171,
        0.052867433951923254,
        0.047197871979547175,
        0.039749301113838446,
        0.0359919561580084,
        0.03004845484711094,
        0.017004773695261526,
        0.00005299094889461365,
        0.000036373420970907194,
        0.000057325537372382036,
        0.00004855197862849841,
        0.00002835575555952761,
        0.0002812849576816708,
        0.00011456922122034789,
        0.0018763617349466474
      ],
      "range": 1
    }
  }
]
