[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE QX1 / prf-solomatov-pred-sony-ilce-qx1-a8693bb03b65@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE QX1 / prf-solomatov-pred-sony-ilce-qx1-a8693bb03b65@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27615726 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27615726; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.010408439741906476,
        0.02251868156571368,
        0.024298448644804772,
        0.0003600273119743439,
        0.012654583841105606,
        0.029517529251267913,
        0.04882875069082015,
        0.07011436165031475,
        0.09682447964612625,
        0.09584118845906857,
        0.0831553369265034,
        0.06766831695824328,
        0.055381140441500616,
        0.033652640528081715,
        0.008685841900372273,
        0.0049276712841081925,
        0.05359074391163933,
        0.2368340415892017,
        0.4958217285325035,
        0.6303270462634224,
        0.6172190077494251,
        0.558463463897346,
        0.4757192695205623,
        0.40648657942217414,
        0.3398279661378448,
        0.27347951670725584,
        0.2140057263024698,
        0.14448970126658991,
        0.08592466480873977,
        0.035702400146930775,
        0.022540919619495066
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE QX1 / prf-solomatov-pred-sony-ilce-qx1-a8693bb03b65@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE QX1 / prf-solomatov-pred-sony-ilce-qx1-a8693bb03b65@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27615726 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27615726; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016090473232534243,
        0.028003750471742077,
        0.05842102431056855,
        0.09635420050155478,
        0.1351010398929943,
        0.16473762087587338,
        0.21398082382480182,
        0.30211832924472093,
        0.4071481589873827,
        0.5173525403605178,
        0.6624222734539008,
        0.838164891989441,
        0.9602120545373313,
        1,
        0.979295528931595,
        0.9145035694516958,
        0.8157671465888675,
        0.6683018219401511,
        0.5079780991453927,
        0.36193609394878845,
        0.24729416854729802,
        0.16326070152926633,
        0.1164951448316079,
        0.07723126308538837,
        0.046691848695196346,
        0.024478112217654533,
        0.013579165001854377,
        0.0013953701597415908,
        0.00003258011214334905,
        0.0027921460402670567,
        0.0004756280895892434
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE QX1 / prf-solomatov-pred-sony-ilce-qx1-a8693bb03b65@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE QX1 / prf-solomatov-pred-sony-ilce-qx1-a8693bb03b65@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27615726 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27615726; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0456401146216471,
        0.11339706948135277,
        0.26745945408062055,
        0.44591313659470694,
        0.5770651838014326,
        0.6773330891246531,
        0.7581343688013127,
        0.7932916556312877,
        0.7812445705754757,
        0.6940151419520891,
        0.5487193420154879,
        0.39034684802420183,
        0.24004292336909774,
        0.1270261589356731,
        0.0705765439590471,
        0.03144006063791333,
        0.020760837502515776,
        0.03519008698159882,
        0.05715012887946527,
        0.051609474253908806,
        0.026118277679898765,
        0.006662871727507725,
        0.0005502421699867677,
        0.0031666178176883706,
        0.013242431504426137,
        0.0196426431084955,
        0.023596043428298786,
        0.01867266136693274,
        0.01050552210722253,
        0.004212987194325436,
        0.00011263870448309053
      ],
      "range": 1
    }
  }
]
