[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony SLT A37 / prf-solomatov-pred-sony-slt-a37-bbc43b03351e@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony SLT A37 / prf-solomatov-pred-sony-slt-a37-bbc43b03351e@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000530298754717 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28105834; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011314523080866412,
        0.02367437247821321,
        0.026342693613344608,
        0.0005796603519364334,
        0.017836534521946258,
        0.03368097460161157,
        0.04768815976689796,
        0.0576026404718618,
        0.07249768344358683,
        0.06793372427770761,
        0.05800338342566173,
        0.05408397891104506,
        0.06182685793167464,
        0.06624484439778587,
        0.0630890077048693,
        0.07879516900299062,
        0.11935808314489336,
        0.24195500640948903,
        0.42505409105233916,
        0.5204234007738181,
        0.490513157636003,
        0.4389816264235914,
        0.3678435943228014,
        0.30336472616043464,
        0.24165702961794333,
        0.18467949777588194,
        0.1360972030025704,
        0.08781335618577617,
        0.04915643372036106,
        0.020332066536667144,
        0.012161120661689973
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony SLT A37 / prf-solomatov-pred-sony-slt-a37-bbc43b03351e@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony SLT A37 / prf-solomatov-pred-sony-slt-a37-bbc43b03351e@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000530298754717 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28105834; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.021852454200433972,
        0.03413344047030652,
        0.06631846163360687,
        0.10645362652515321,
        0.14544916126019178,
        0.17318688813464447,
        0.22260970212741626,
        0.3213708903949386,
        0.44095533021720684,
        0.5615773230713652,
        0.7053967912853965,
        0.8713054518203182,
        0.9739062818225404,
        1,
        0.9578000016598636,
        0.8762422647327822,
        0.7619006806050099,
        0.6170262379527275,
        0.4635733346199643,
        0.3202110582257629,
        0.20222927619463865,
        0.11679169760889395,
        0.07276821453028279,
        0.049173653062874065,
        0.033687643929192775,
        0.022291979993576037,
        0.02039084440187001,
        0.010688995016203354,
        0.005800207184533918,
        0.005255534372922954,
        0.0017962509786605665
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony SLT A37 / prf-solomatov-pred-sony-slt-a37-bbc43b03351e@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony SLT A37 / prf-solomatov-pred-sony-slt-a37-bbc43b03351e@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000530298754717 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28105834; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06279861060162811,
        0.14854485883259821,
        0.33955848259966576,
        0.5504915812140639,
        0.6929744728443211,
        0.7981963973901093,
        0.8762302795429836,
        0.8992484234729919,
        0.8739233388935075,
        0.7581182487970726,
        0.5830206789095815,
        0.3969184001679746,
        0.22896855650626183,
        0.10944224248958417,
        0.058978651707842736,
        0.030310804381881582,
        0.03221515942968587,
        0.03610846766709054,
        0.035557656635543576,
        0.030318733162514662,
        0.02955621372654042,
        0.026696946298893194,
        0.018504223983556053,
        0.007510844093848533,
        0.000006402803551390789,
        0.00002659835370287015,
        0.00013736695609714035,
        0.000007438368611756399,
        0.00006296392806895955,
        0.0000855692253084888,
        0.00012164366002141354
      ],
      "range": 1
    }
  }
]
