    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 II Ultra wide angle Camera / prf-solomatov-pred-sony-xperia-1-ii-ultra-wide-angle-camera-c49e5a8cf7ec@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 II Ultra wide angle Camera / prf-solomatov-pred-sony-xperia-1-ii-ultra-wide-angle-camera-c49e5a8cf7ec@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00050695290566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26868504; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01613553035926377,
        0.02898278741206415,
        0.02792976162367514,
        0.000060246947547313804,
        0.00010778550958603969,
        0.011206638159765882,
        0.04233772051631451,
        0.07245682480997241,
        0.11366017554419854,
        0.1177426762333675,
        0.106322116705865,
        0.09475093684003384,
        0.07856016865580723,
        0.048749781528588276,
        0.009345972959709698,
        0.0017246869379444832,
        0.042092977285651215,
        0.2326822937499936,
        0.5307326627643204,
        0.6702221193600975,
        0.6324903419756208,
        0.5610391155872123,
        0.47174306224264334,
        0.39914756107261656,
        0.33472410845334005,
        0.26769514338309386,
        0.20933278506042888,
        0.14101298069371096,
        0.07872104064998317,
        0.028641943866072092,
        0.02174445711071755
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 II Ultra wide angle Camera / prf-solomatov-pred-sony-xperia-1-ii-ultra-wide-angle-camera-c49e5a8cf7ec@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 II Ultra wide angle Camera / prf-solomatov-pred-sony-xperia-1-ii-ultra-wide-angle-camera-c49e5a8cf7ec@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00050695290566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26868504; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02454585497205204,
        0.03854027595048037,
        0.07165915464937436,
        0.1112105090397569,
        0.1512550754593557,
        0.18929481315537497,
        0.2524562175588321,
        0.3676986561204137,
        0.5043158703278259,
        0.6277339923992155,
        0.7604446797633393,
        0.9061646144730444,
        0.990507952531164,
        1,
        0.9559929936580793,
        0.8757817981028847,
        0.7718620603939416,
        0.6354560989641294,
        0.4843901618043193,
        0.3481293016499284,
        0.24019933339050065,
        0.16147458779977933,
        0.1141448967954834,
        0.07710756312498711,
        0.04828665365496346,
        0.02787970090871511,
        0.018159725794614962,
        0.0067929928485184025,
        0.0030673866761048774,
        0.004350314906935678,
        0.00017731823183860822
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 II Ultra wide angle Camera / prf-solomatov-pred-sony-xperia-1-ii-ultra-wide-angle-camera-c49e5a8cf7ec@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 II Ultra wide angle Camera / prf-solomatov-pred-sony-xperia-1-ii-ultra-wide-angle-camera-c49e5a8cf7ec@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00050695290566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26868504; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.059987317678721536,
        0.1431608276639335,
        0.3275410849960591,
        0.5424100917911259,
        0.6819334350462061,
        0.770609384628684,
        0.8246767657127793,
        0.8257634299727518,
        0.776900813867419,
        0.6767063391244945,
        0.5380118290173507,
        0.40698180351560614,
        0.2848370709723635,
        0.1939171901792523,
        0.14293103539729254,
        0.10227319013302039,
        0.07684931929433597,
        0.06895641389100564,
        0.0737889360127305,
        0.05682882033330468,
        0.025959472473793113,
        0.0035750984699774732,
        0.00013570636705821182,
        0.0018968002786093293,
        0.009781133835875271,
        0.016916227668247956,
        0.02056791374492874,
        0.016572969267093403,
        0.009863222129348703,
        0.003447882226390586,
        0.004014239880482899
      ],
      "range": 1
    }
  }
]