[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 III Ultra wide angle Camera / prf-solomatov-pred-sony-xperia-1-iii-ultra-wide-angle-camera-1250e3443918@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 III Ultra wide angle Camera / prf-solomatov-pred-sony-xperia-1-iii-ultra-wide-angle-camera-1250e3443918@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000496370943396 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2630766; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02091144261785351,
        0.03330422829830348,
        0.03000930138290702,
        0.00008962366147173441,
        0.000010863617547823783,
        0.0009529987505962565,
        0.04293471195643498,
        0.0879719572331987,
        0.14523373959016755,
        0.14846839223532118,
        0.12631033470859818,
        0.09594322956679151,
        0.05728673592230728,
        0.00010706390078022904,
        0.00001304491107096508,
        2.381547358519085e-7,
        0.00013461322732890072,
        0.22282049850839925,
        0.5811813142557378,
        0.7241574745575488,
        0.6773430995636506,
        0.5971585723901173,
        0.5056933473049785,
        0.4361846393968977,
        0.376125366742044,
        0.30974167863013163,
        0.24522520563719213,
        0.167568120928992,
        0.09148635064285236,
        0.03682280612445637,
        0.029704400760625832
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 III Ultra wide angle Camera / prf-solomatov-pred-sony-xperia-1-iii-ultra-wide-angle-camera-1250e3443918@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 III Ultra wide angle Camera / prf-solomatov-pred-sony-xperia-1-iii-ultra-wide-angle-camera-1250e3443918@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000496370943396 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2630766; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.024870790009449723,
        0.04035066972889265,
        0.07561538694342981,
        0.12174436461330239,
        0.16692959389014456,
        0.20501073333351919,
        0.2636819508412974,
        0.36689706554361545,
        0.49484430263530355,
        0.6151715151109788,
        0.7445927786811902,
        0.8917675300802945,
        0.9826538281128884,
        1,
        0.9664071070020137,
        0.8964438729321353,
        0.800804328473152,
        0.6629664822723703,
        0.5141493403245578,
        0.38231663982586656,
        0.2852500572076726,
        0.20761670885533892,
        0.1568127777968654,
        0.10726762724874303,
        0.06816347257557305,
        0.03575264443307211,
        0.019635535118599747,
        0.0061082709398945735,
        0.0028234868637678377,
        0.0042905610882473235,
        0.00007299076667621305
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 III Ultra wide angle Camera / prf-solomatov-pred-sony-xperia-1-iii-ultra-wide-angle-camera-1250e3443918@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 III Ultra wide angle Camera / prf-solomatov-pred-sony-xperia-1-iii-ultra-wide-angle-camera-1250e3443918@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000496370943396 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2630766; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06082727122062548,
        0.14329615729281334,
        0.33434339746710745,
        0.5607874682321281,
        0.6957182838831664,
        0.7724642776201981,
        0.8222230050437617,
        0.8084262020861783,
        0.7437393947238181,
        0.6343989064285414,
        0.4953038756012507,
        0.3701731902941025,
        0.264914897702506,
        0.18776487532528552,
        0.14466183120697054,
        0.10877636205922188,
        0.08494874618810101,
        0.08801517498118853,
        0.09833851066374873,
        0.0746040507477638,
        0.03476023203254617,
        0.006064431411692685,
        0.00044195930681099557,
        0.00028618062342612537,
        0.007061140242756293,
        0.013067988943144319,
        0.01645386034471951,
        0.01362149019851332,
        0.00685289289596754,
        0.001796526348136858,
        0.002516903686172447
      ],
      "range": 1
    }
  }
]
