[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 5 IV Wide Camera / prf-solomatov-pred-sony-xperia-5-iv-wide-camera-e339879ebf5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 5 IV Wide Camera / prf-solomatov-pred-sony-xperia-5-iv-wide-camera-e339879ebf5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000502388603774 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26626596; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018931164398558496,
        0.03326500179213808,
        0.03563351653397692,
        0.000021065281661185853,
        0.000017898837628703683,
        0.014314455541619614,
        0.0502689807328112,
        0.08432242533711366,
        0.12897487276443448,
        0.130395896230205,
        0.1150094599399788,
        0.09786686184583498,
        0.07545556005212001,
        0.028393195284894847,
        0.00016111354935827653,
        0.0002442345499555817,
        0.00025469866234229004,
        0.268028156324891,
        0.606694590574803,
        0.7070389721538799,
        0.6506469577761023,
        0.5725696340556958,
        0.48037023619832664,
        0.406947704134284,
        0.33956215361700753,
        0.2696744476549225,
        0.20232421281930202,
        0.12946796436501126,
        0.07110332466080155,
        0.027766841888441925,
        0.023850174196399072
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 5 IV Wide Camera / prf-solomatov-pred-sony-xperia-5-iv-wide-camera-e339879ebf5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 5 IV Wide Camera / prf-solomatov-pred-sony-xperia-5-iv-wide-camera-e339879ebf5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000502388603774 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26626596; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.025455482875092254,
        0.03951237290128645,
        0.07636023511801436,
        0.1165522985032063,
        0.1622515361913124,
        0.20134800324374086,
        0.26215754941118796,
        0.3745380899800575,
        0.5056071098986892,
        0.6263406163904844,
        0.7566111514967967,
        0.9007237615308525,
        0.9883224248070209,
        1,
        0.9629876451906012,
        0.8842533382787645,
        0.7840746697131586,
        0.6432390434117405,
        0.4925627874035264,
        0.3614693418641793,
        0.25465403150544164,
        0.17647340891544777,
        0.12692240725364679,
        0.08854173837412026,
        0.05761134116617836,
        0.0338962398578994,
        0.023494018741807832,
        0.012089408773227419,
        0.005278414213897926,
        0.006121970886073697,
        0.0007468068344683853
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 5 IV Wide Camera / prf-solomatov-pred-sony-xperia-5-iv-wide-camera-e339879ebf5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 5 IV Wide Camera / prf-solomatov-pred-sony-xperia-5-iv-wide-camera-e339879ebf5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000502388603774 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26626596; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06235367853630257,
        0.14085624196125138,
        0.3226534745292156,
        0.5441945024737933,
        0.6843412597689918,
        0.7657060632158913,
        0.8163827094892836,
        0.8127387400592393,
        0.753143203603645,
        0.651338421178584,
        0.5151205223529136,
        0.3888469464523219,
        0.2781483238817655,
        0.19672604789587073,
        0.15182514421962828,
        0.11537959681023782,
        0.09345344634794045,
        0.09131130972903802,
        0.09462174813276272,
        0.06891803205374691,
        0.03639954515152194,
        0.013695682390915198,
        0.0032439590633122923,
        0.0034628445743520304,
        0.007511317813352859,
        0.009694932679051714,
        0.011030996579282585,
        0.008032859393331569,
        0.004217891433680466,
        0.0017942606185445428,
        0.0027126852253824925
      ],
      "range": 1
    }
  }
]
