    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 12S Ultra Rear Telephoto Camera / prf-solomatov-pred-xiaomi-12s-ultra-rear-telephoto-camera-33637de7b9be@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 12S Ultra Rear Telephoto Camera / prf-solomatov-pred-xiaomi-12s-ultra-rear-telephoto-camera-33637de7b9be@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000513740943396 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2722827; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01464413065905399,
        0.029229546188933638,
        0.02899883167646819,
        0.002790540179080803,
        0.006628085876119996,
        0.022284534501171842,
        0.04902591872983164,
        0.07385669153045243,
        0.10641915905172578,
        0.11169495078280846,
        0.10334738681524754,
        0.09490306891747899,
        0.0812444492433783,
        0.04912485626152525,
        0.013025628197512419,
        0.0023174403662076216,
        0.04607869898244939,
        0.2800749931996311,
        0.5616393328166542,
        0.6617426729458583,
        0.6189498567726361,
        0.547615508970134,
        0.4598941758078123,
        0.38570192927575897,
        0.32356050921523843,
        0.26042029733180877,
        0.20199533259165767,
        0.1369902058938315,
        0.07777138386813756,
        0.03424110575015482,
        0.024527514758951426
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 12S Ultra Rear Telephoto Camera / prf-solomatov-pred-xiaomi-12s-ultra-rear-telephoto-camera-33637de7b9be@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 12S Ultra Rear Telephoto Camera / prf-solomatov-pred-xiaomi-12s-ultra-rear-telephoto-camera-33637de7b9be@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000513740943396 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2722827; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.025223656332187098,
        0.038060242480942974,
        0.0703214250343135,
        0.10506079620855072,
        0.14482552583967123,
        0.18456859563812006,
        0.25148112844544995,
        0.37023693514287004,
        0.5097082148749565,
        0.635558271770105,
        0.7701508806839362,
        0.9136956070390998,
        0.9932520967814249,
        1,
        0.9515044548810374,
        0.8713136744206731,
        0.7643967563072183,
        0.6201516929589029,
        0.4717458108923126,
        0.33943812529142736,
        0.23441769283664857,
        0.155092767945071,
        0.11060162950658127,
        0.07456446897473816,
        0.04715493102389538,
        0.02615210316901684,
        0.018579522691049788,
        0.009077047692458403,
        0.0031728574209603385,
        0.004993631666806149,
        0.0017088353239377413
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 12S Ultra Rear Telephoto Camera / prf-solomatov-pred-xiaomi-12s-ultra-rear-telephoto-camera-33637de7b9be@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 12S Ultra Rear Telephoto Camera / prf-solomatov-pred-xiaomi-12s-ultra-rear-telephoto-camera-33637de7b9be@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000513740943396 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2722827; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.053876433941634924,
        0.13279724219914296,
        0.31222628959848403,
        0.5300410984441862,
        0.6712329785449929,
        0.7484360539819663,
        0.7979174194608254,
        0.7872827091186023,
        0.7313154872368558,
        0.6343647058662162,
        0.5045463931421276,
        0.38474487700308774,
        0.27640693138757283,
        0.19680010885744853,
        0.1497663240230616,
        0.11165771176928845,
        0.08433585584289523,
        0.0757767539321989,
        0.0738901590148768,
        0.050524359673958755,
        0.016465366333104036,
        0.000019473951527729613,
        0.00009620461250443487,
        0.00004681566790808766,
        0.005586878597364063,
        0.012971063022140083,
        0.017778012432510683,
        0.01495867746849961,
        0.00846736552509147,
        0.004630222883810823,
        0.004275264521553728
      ],
      "range": 1
    }
  }
]