[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 13 Pro Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-13-pro-rear-ultrawide-camera-39901aa24e09@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 13 Pro Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-13-pro-rear-ultrawide-camera-39901aa24e09@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000521493075472 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27639133; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014256145190950819,
        0.026345747945979877,
        0.027834532489719944,
        0.00023613144147029036,
        0.009988202876236125,
        0.02402431601438278,
        0.04589566547452531,
        0.06516045803453556,
        0.09356557203090754,
        0.0976784292748685,
        0.08990109400320193,
        0.0814411580855304,
        0.07036231048536537,
        0.04413509280482858,
        0.011378488856790547,
        0.00015216058398726976,
        0.04597236429490855,
        0.2566810419176445,
        0.5221186463011177,
        0.628833186798796,
        0.5929215513622177,
        0.5259528522861254,
        0.4438595106578451,
        0.37559790752607625,
        0.31447271586811354,
        0.2548415577179034,
        0.19748543695548476,
        0.13141698516170114,
        0.07299739924803678,
        0.0316173803700507,
        0.02335291383519778
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 13 Pro Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-13-pro-rear-ultrawide-camera-39901aa24e09@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 13 Pro Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-13-pro-rear-ultrawide-camera-39901aa24e09@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000521493075472 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27639133; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.021415707658051363,
        0.033424991209419476,
        0.06383730383121572,
        0.10183834747032618,
        0.13645720280996973,
        0.16460558609659237,
        0.22348712272181814,
        0.33416238975522694,
        0.46481563575396284,
        0.5923903574526387,
        0.7367947496761206,
        0.8934311099595564,
        0.9871926566804895,
        1,
        0.9569008134897665,
        0.8771061812973657,
        0.7699304738631687,
        0.621674702657051,
        0.46759919325629534,
        0.33442132788036566,
        0.23159667056126546,
        0.15507450145023738,
        0.11023213821621171,
        0.07434875996578348,
        0.04642667410415877,
        0.023685795732505014,
        0.01300161747826785,
        0.004344242225568958,
        0.0012060591025476984,
        0.003707109403723788,
        0.0001438413839846982
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 13 Pro Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-13-pro-rear-ultrawide-camera-39901aa24e09@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 13 Pro Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-13-pro-rear-ultrawide-camera-39901aa24e09@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000521493075472 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27639133; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.058164454000782156,
        0.13973541012903168,
        0.32815949589956217,
        0.5438059408586151,
        0.6821004018929512,
        0.7647067768410504,
        0.8184039636843892,
        0.8090596809841892,
        0.751408666955412,
        0.6413408186021418,
        0.4941308947715546,
        0.3571028184609715,
        0.23879666586112913,
        0.15510740875989126,
        0.11168150138321527,
        0.0752890952246453,
        0.05533680859309154,
        0.056987545806691436,
        0.06518113459911577,
        0.04790405353089987,
        0.012327118937968617,
        0.00009419277263479297,
        0.000009338393256612154,
        0.000007692039921962981,
        0.006469731759042514,
        0.016752776468172026,
        0.02179728149478232,
        0.017767165408596356,
        0.00999167855058772,
        0.003868991303648755,
        0.004389038417790767
      ],
      "range": 1
    }
  }
]
