    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 13 Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-13-rear-ultrawide-camera-ca13909728fa@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 13 Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-13-rear-ultrawide-camera-ca13909728fa@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00050132490566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2657022; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016507571550028566,
        0.029040333473651807,
        0.03137229315197168,
        0.000001585931812487465,
        0.00472983591814787,
        0.02839472821661076,
        0.06549064475681551,
        0.09653307365371153,
        0.1409299123228938,
        0.13736141408828134,
        0.11407979008077464,
        0.08718799571290642,
        0.05979565855625642,
        0.016054248704000195,
        0.000016036240322185265,
        0.00006433599810751901,
        0.000044981511054212466,
        0.21496633066062734,
        0.5345630604748345,
        0.6759264140614466,
        0.6384145884628228,
        0.5701319464385932,
        0.48339123346945706,
        0.418325389662586,
        0.35895436989701257,
        0.29759042613526315,
        0.2389496769258397,
        0.16833095473052162,
        0.09794778625889304,
        0.039297454666992936,
        0.029585085106559147
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 13 Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-13-rear-ultrawide-camera-ca13909728fa@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 13 Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-13-rear-ultrawide-camera-ca13909728fa@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00050132490566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2657022; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.023830874179814845,
        0.0387632213625704,
        0.0766456653530227,
        0.12221520857071441,
        0.16822237879988813,
        0.20937779723147026,
        0.26814680937498087,
        0.3768416110456857,
        0.5089449169972999,
        0.6298455994288772,
        0.7602579399041484,
        0.9035374433128075,
        0.9879897059999446,
        1,
        0.9599865870442478,
        0.8858451139522505,
        0.7869833212575152,
        0.6478512812530509,
        0.4946388520941737,
        0.36049965917622384,
        0.25895601541876584,
        0.18019159512379515,
        0.13120482873367736,
        0.08717357789499457,
        0.053976198258802524,
        0.028060497284322302,
        0.015266389372855182,
        0.0032149436923755185,
        0.0016062933316277528,
        0.0032711110135844683,
        0.0000827599731149062
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 13 Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-13-rear-ultrawide-camera-ca13909728fa@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 13 Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-13-rear-ultrawide-camera-ca13909728fa@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00050132490566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2657022; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06464566119512748,
        0.1512173805219785,
        0.3457885826419847,
        0.5659276079201312,
        0.6971852270563196,
        0.775902050407478,
        0.8303567981126173,
        0.8237941222853927,
        0.77108518641045,
        0.662726634156125,
        0.523201893699036,
        0.3939840753604423,
        0.27860854760879483,
        0.1931481184574309,
        0.14305657890954887,
        0.10285499548674486,
        0.07629499337711813,
        0.07179033057283615,
        0.08026346523703397,
        0.05894553088867212,
        0.02127886934445155,
        0.0015578019548102239,
        0.000021945576427657634,
        0.00003739573692437839,
        0.008199643429514321,
        0.015577306461606554,
        0.02020534449789458,
        0.016592237879335163,
        0.010255998538965805,
        0.0036857771540872624,
        0.003266380137505179
      ],
      "range": 1
    }
  }
]