    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi Mi 11 Lite Front Camera / prf-solomatov-pred-xiaomi-mi-11-lite-front-camera-612004aeb8ea@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi Mi 11 Lite Front Camera / prf-solomatov-pred-xiaomi-mi-11-lite-front-camera-612004aeb8ea@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000495943924528 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26285028; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01729188790477986,
        0.03005498963692721,
        0.023450748871725977,
        0.0012450354034951175,
        0.0009967363117755234,
        0.00004446270147908282,
        0.029416338473551656,
        0.0716527987444638,
        0.12197974308796627,
        0.12382368458296984,
        0.10207949224935199,
        0.07782820908168561,
        0.04810471734356503,
        0.0023025214201788176,
        0.000022751053685320335,
        0.00001866652017469966,
        0.0018230229228376157,
        0.21629385400585954,
        0.543163395868002,
        0.6932027552151923,
        0.6657503338656009,
        0.5961479106885549,
        0.507187283022254,
        0.4391672577509397,
        0.3776056502821682,
        0.31017697164391017,
        0.246811505520684,
        0.17326753658950902,
        0.10240370252735871,
        0.040240049295886926,
        0.02708372728383626
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi Mi 11 Lite Front Camera / prf-solomatov-pred-xiaomi-mi-11-lite-front-camera-612004aeb8ea@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi Mi 11 Lite Front Camera / prf-solomatov-pred-xiaomi-mi-11-lite-front-camera-612004aeb8ea@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000495943924528 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26285028; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.022822655829014146,
        0.03814430750203908,
        0.07584402964520878,
        0.1194781269256364,
        0.16282267392607755,
        0.1986303504962766,
        0.2547207681018689,
        0.35764190468898893,
        0.48341633796877315,
        0.6058521518603749,
        0.7394834412959347,
        0.8888502125807207,
        0.9830138567856956,
        1,
        0.9620259515825538,
        0.8903703825753443,
        0.7913587285996315,
        0.655224366683627,
        0.509285295744052,
        0.37666262884569546,
        0.27593963060137,
        0.19804230315472968,
        0.14772945200051013,
        0.10104654610414696,
        0.06406006806660049,
        0.03573417641755252,
        0.019905853836432872,
        0.00643750078402842,
        0.002027553318565991,
        0.0034960374852332594,
        0.0004458635409154921
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi Mi 11 Lite Front Camera / prf-solomatov-pred-xiaomi-mi-11-lite-front-camera-612004aeb8ea@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi Mi 11 Lite Front Camera / prf-solomatov-pred-xiaomi-mi-11-lite-front-camera-612004aeb8ea@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000495943924528 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26285028; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0631685276310149,
        0.1527456076200768,
        0.34927561460173484,
        0.5759485349394288,
        0.7161710054795521,
        0.801342074532569,
        0.856107350310338,
        0.8491797380428645,
        0.7866306415005531,
        0.6714234228469437,
        0.5210796769933059,
        0.3828317457703581,
        0.26237901587345286,
        0.17794323825715536,
        0.13435720369448004,
        0.10329634096434878,
        0.08621737982767767,
        0.0844225113126838,
        0.08884196494699935,
        0.06876868568728782,
        0.038429196778231825,
        0.015288352571275027,
        0.004075218464732582,
        0.0033716628666761493,
        0.006688019221436629,
        0.00793169355690887,
        0.009989073783406625,
        0.008158244793797476,
        0.005135486607231534,
        0.0016507689682021506,
        0.000979594533000742
      ],
      "range": 1
    }
  }
]