    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi Mi 11 Lite Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-mi-11-lite-rear-ultrawide-camera-641369add105@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi Mi 11 Lite Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-mi-11-lite-rear-ultrawide-camera-641369add105@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26575693 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26575693; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014781832782309759,
        0.025425252316092002,
        0.022188358361906125,
        0.00013252705018830554,
        0.0000153416733102689,
        0.000014618666764400087,
        0.02279705368360479,
        0.06848621407539589,
        0.12375705499006177,
        0.12434640180408466,
        0.1098906132005664,
        0.08711480073163097,
        0.0629926790620286,
        0.013301143266518017,
        0.00003207144212570487,
        0.00003257017229992836,
        0.000011534432987316642,
        0.27090010409135895,
        0.6861452305307711,
        0.8365279505599347,
        0.7828651918879407,
        0.7061284159175077,
        0.6091731267365257,
        0.5333913211595273,
        0.46143650891813054,
        0.3775510952809396,
        0.2971444996749473,
        0.2037692563652056,
        0.1152580292073663,
        0.04888659347472143,
        0.036651017905723095
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi Mi 11 Lite Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-mi-11-lite-rear-ultrawide-camera-641369add105@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi Mi 11 Lite Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-mi-11-lite-rear-ultrawide-camera-641369add105@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26575693 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26575693; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018500337883945304,
        0.030200288662274956,
        0.06099977524574806,
        0.09330466001394583,
        0.13477589088645778,
        0.17139262558458965,
        0.22453051365396193,
        0.3248924647044952,
        0.450046852964474,
        0.5732726141892142,
        0.7119497881014806,
        0.8646948924342255,
        0.9693794250257181,
        1,
        0.980897468976632,
        0.9204731933048744,
        0.8292578485159352,
        0.6987805360334347,
        0.5559167920851584,
        0.42130901346580124,
        0.31006115249750965,
        0.22287892925313368,
        0.16677108664673393,
        0.12034521545684622,
        0.08373258601384355,
        0.05304376822835815,
        0.038438745510794396,
        0.022069232211555122,
        0.011359186381329735,
        0.009415209228974764,
        0.002845874085014453
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi Mi 11 Lite Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-mi-11-lite-rear-ultrawide-camera-641369add105@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi Mi 11 Lite Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-mi-11-lite-rear-ultrawide-camera-641369add105@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26575693 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26575693; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04337229136414241,
        0.10914832587808716,
        0.2603635397203,
        0.4482953087996614,
        0.5640680000329624,
        0.6278775119805907,
        0.6726152729112275,
        0.6595031030799461,
        0.5946437219906175,
        0.49957959704004706,
        0.39141585131947454,
        0.30264490186577636,
        0.23565275983583944,
        0.19401702901971363,
        0.17542044905470575,
        0.16181105042114988,
        0.1516816212469041,
        0.14727197518424073,
        0.14030420203905877,
        0.11254247255189169,
        0.08193870993317089,
        0.05590666252804772,
        0.0376045697096215,
        0.024191506125541107,
        0.016102734555219312,
        0.010082251853225426,
        0.006574313603035676,
        0.0036677560957676628,
        0.0018309980477272973,
        0.0003716512867604243,
        0.0006404157362895484
      ],
      "range": 1
    }
  }
]