  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone 6s",
        "source_url": "https://docs.google.com/uc?export=download&id=1dQExKthDjb45N7o5T5QWUTeKELxM03AH"
      },
      "uncertainty": null,
      "values": [
        0.0242,
        0.0318,
        0.0381,
        0.034,
        0.0279,
        0.0237,
        0.0232,
        0.0265,
        0.0307,
        0.0349,
        0.0421,
        0.0582,
        0.0739,
        0.0726,
        0.058,
        0.051,
        0.0638,
        0.191,
        0.478,
        0.684,
        0.692,
        0.616,
        0.535,
        0.468,
        0.391,
        0.323,
        0.265,
        0.196,
        0.106,
        0.033,
        0.0133
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone 6s",
        "source_url": "https://docs.google.com/uc?export=download&id=1dQExKthDjb45N7o5T5QWUTeKELxM03AH"
      },
      "uncertainty": null,
      "values": [
        0.0265,
        0.0284,
        0.0321,
        0.0361,
        0.0427,
        0.0533,
        0.119,
        0.302,
        0.575,
        0.812,
        0.925,
        0.987,
        0.998,
        0.985,
        0.959,
        0.913,
        0.791,
        0.702,
        0.577,
        0.449,
        0.311,
        0.202,
        0.136,
        0.103,
        0.0794,
        0.0643,
        0.0572,
        0.0498,
        0.0336,
        0.0151,
        0.00931
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone 6s",
        "source_url": "https://docs.google.com/uc?export=download&id=1dQExKthDjb45N7o5T5QWUTeKELxM03AH"
      },
      "uncertainty": null,
      "values": [
        0.0875,
        0.268,
        0.466,
        0.579,
        0.657,
        0.698,
        0.709,
        0.696,
        0.643,
        0.541,
        0.408,
        0.289,
        0.201,
        0.147,
        0.109,
        0.0797,
        0.055,
        0.0454,
        0.0406,
        0.0362,
        0.0306,
        0.0255,
        0.0229,
        0.0234,
        0.0239,
        0.0248,
        0.0253,
        0.0223,
        0.0142,
        0.00541,
        0.00296
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-00-fde6a17ea4",
  "id": "ohtera2021-ohtera-txt-00-fde6a17ea4",
  "kind": "camera",
  "label": "Apple iPhone 6s · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Apple",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "iPhone 6s",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-00",
    "generational_ambiguity": null,
    "profile_prefix": "ohtera2021:ohtera-txt-00",
    "source_asset_id": "ohtera-txt-00",
    "source_asset_sha256": "d1511879d1b5c40548805cc46e3a9a53584526c9acdd69ed9d269ba29dda7f93",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}