  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone SE",
        "source_url": "https://docs.google.com/uc?export=download&id=1dMec6PkUiH8Hk38Mp-om-3Dy5j40xtp7"
      },
      "uncertainty": null,
      "values": [
        0.0105,
        0.0158,
        0.0373,
        0.0379,
        0.0303,
        0.025,
        0.0212,
        0.0234,
        0.0295,
        0.0329,
        0.0364,
        0.0469,
        0.0678,
        0.0851,
        0.0693,
        0.0508,
        0.0482,
        0.0617,
        0.251,
        0.657,
        0.736,
        0.669,
        0.581,
        0.506,
        0.439,
        0.364,
        0.298,
        0.239,
        0.148,
        0.0496,
        0.0122
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone SE",
        "source_url": "https://docs.google.com/uc?export=download&id=1dMec6PkUiH8Hk38Mp-om-3Dy5j40xtp7"
      },
      "uncertainty": null,
      "values": [
        0.0146,
        0.0148,
        0.0269,
        0.0282,
        0.0336,
        0.0396,
        0.0461,
        0.132,
        0.427,
        0.74,
        0.892,
        0.982,
        1,
        0.993,
        0.978,
        0.93,
        0.852,
        0.758,
        0.65,
        0.52,
        0.379,
        0.244,
        0.151,
        0.107,
        0.0848,
        0.0674,
        0.0567,
        0.0532,
        0.0427,
        0.0205,
        0.00965
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone SE",
        "source_url": "https://docs.google.com/uc?export=download&id=1dMec6PkUiH8Hk38Mp-om-3Dy5j40xtp7"
      },
      "uncertainty": null,
      "values": [
        0.0149,
        0.0829,
        0.35,
        0.519,
        0.592,
        0.671,
        0.699,
        0.694,
        0.666,
        0.606,
        0.481,
        0.349,
        0.229,
        0.154,
        0.119,
        0.087,
        0.0591,
        0.0454,
        0.0406,
        0.038,
        0.0328,
        0.0267,
        0.0224,
        0.0214,
        0.0224,
        0.0238,
        0.0249,
        0.0251,
        0.019,
        0.00825,
        0.00405
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-01-fc2ef3e527",
  "id": "ohtera2021-ohtera-txt-01-fc2ef3e527",
  "kind": "camera",
  "label": "Apple iPhone SE · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Apple",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "iPhone SE",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-01",
    "generational_ambiguity": "Model label is iPhone SE; generation not established by intake evidence.",
    "profile_prefix": "ohtera2021:ohtera-txt-01",
    "source_asset_id": "ohtera-txt-01",
    "source_asset_sha256": "0dd185167a4d95e861b905880bc0be49e5a7739e3c822450c37afeae18f40e88",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}