{
  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone 8",
        "source_url": "https://docs.google.com/uc?export=download&id=1dOp0-yXR9MnDbuc5mVOO2izRFkqQICGD"
      },
      "uncertainty": null,
      "values": [
        0.00651,
        0.0134,
        0.0172,
        0.0167,
        0.0153,
        0.0135,
        0.0126,
        0.0133,
        0.0189,
        0.0237,
        0.0305,
        0.0406,
        0.0608,
        0.0763,
        0.0559,
        0.0436,
        0.0434,
        0.0562,
        0.385,
        0.748,
        0.738,
        0.646,
        0.523,
        0.419,
        0.326,
        0.234,
        0.179,
        0.119,
        0.0528,
        0.0253,
        0.0209
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone 8",
        "source_url": "https://docs.google.com/uc?export=download&id=1dOp0-yXR9MnDbuc5mVOO2izRFkqQICGD"
      },
      "uncertainty": null,
      "values": [
        0.0059,
        0.0101,
        0.0184,
        0.0188,
        0.0247,
        0.0513,
        0.0449,
        0.0468,
        0.177,
        0.56,
        0.804,
        0.934,
        0.947,
        1,
        0.954,
        0.924,
        0.847,
        0.723,
        0.627,
        0.471,
        0.314,
        0.169,
        0.0876,
        0.0529,
        0.0384,
        0.029,
        0.0254,
        0.0219,
        0.0187,
        0.0162,
        0.018
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone 8",
        "source_url": "https://docs.google.com/uc?export=download&id=1dOp0-yXR9MnDbuc5mVOO2izRFkqQICGD"
      },
      "uncertainty": null,
      "values": [
        0.0115,
        0.121,
        0.259,
        0.37,
        0.452,
        0.521,
        0.549,
        0.549,
        0.571,
        0.499,
        0.397,
        0.288,
        0.177,
        0.133,
        0.105,
        0.0784,
        0.0532,
        0.0432,
        0.0406,
        0.0366,
        0.0313,
        0.025,
        0.0217,
        0.0214,
        0.0219,
        0.0217,
        0.0233,
        0.0215,
        0.0182,
        0.0158,
        0.0184
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-02-2a49d8870c",
  "id": "ohtera2021-ohtera-txt-02-2a49d8870c",
  "kind": "camera",
  "label": "Apple iPhone 8 · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Apple",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "iPhone 8",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-02",
    "generational_ambiguity": null,
    "profile_prefix": "ohtera2021:ohtera-txt-02",
    "source_asset_id": "ohtera-txt-02",
    "source_asset_sha256": "9a121a8ba49adb74b42eaeffe03efa435ed369baa3f7bb81b46ae0ba6ea82f15",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}
