  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone X",
        "source_url": "https://docs.google.com/uc?export=download&id=1dKYksvsFi5BUUA_8aRG4uHUv-eZV-6k9"
      },
      "uncertainty": null,
      "values": [
        0.0196,
        0.0183,
        0.0206,
        0.0193,
        0.0176,
        0.0148,
        0.0139,
        0.0158,
        0.0214,
        0.0282,
        0.0373,
        0.0472,
        0.0681,
        0.0819,
        0.066,
        0.0515,
        0.05,
        0.0658,
        0.312,
        0.703,
        0.711,
        0.623,
        0.547,
        0.432,
        0.311,
        0.239,
        0.172,
        0.105,
        0.0493,
        0.0166,
        0.00879
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone X",
        "source_url": "https://docs.google.com/uc?export=download&id=1dKYksvsFi5BUUA_8aRG4uHUv-eZV-6k9"
      },
      "uncertainty": null,
      "values": [
        0.0244,
        0.019,
        0.0239,
        0.0261,
        0.034,
        0.0573,
        0.06,
        0.0695,
        0.202,
        0.495,
        0.796,
        0.919,
        0.986,
        1,
        0.968,
        0.903,
        0.823,
        0.724,
        0.619,
        0.463,
        0.312,
        0.176,
        0.101,
        0.0574,
        0.0358,
        0.0268,
        0.0204,
        0.0157,
        0.0115,
        0.0081,
        0.00715
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone X",
        "source_url": "https://docs.google.com/uc?export=download&id=1dKYksvsFi5BUUA_8aRG4uHUv-eZV-6k9"
      },
      "uncertainty": null,
      "values": [
        0.0451,
        0.14,
        0.268,
        0.384,
        0.468,
        0.543,
        0.587,
        0.615,
        0.599,
        0.533,
        0.425,
        0.311,
        0.205,
        0.143,
        0.112,
        0.0809,
        0.0597,
        0.0479,
        0.0433,
        0.0373,
        0.0294,
        0.0211,
        0.0167,
        0.0139,
        0.0129,
        0.0131,
        0.0124,
        0.0099,
        0.00638,
        0.00408,
        0.00371
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-03-3386081449",
  "id": "ohtera2021-ohtera-txt-03-3386081449",
  "kind": "camera",
  "label": "Apple iPhone X · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Apple",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "iPhone X",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-03",
    "generational_ambiguity": null,
    "profile_prefix": "ohtera2021:ohtera-txt-03",
    "source_asset_id": "ohtera-txt-03",
    "source_asset_sha256": "63f992d333794e639f4b4f28f44cab8054ebb27acadfa651633d384f81ac71ce",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}