{
  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone 11",
        "source_url": "https://docs.google.com/uc?export=download&id=1d_lhS5r2uW3JuFV58Bn93hjtV_RLPQoV"
      },
      "uncertainty": null,
      "values": [
        0.0168,
        0.0107,
        0.0137,
        0.0193,
        0.0211,
        0.0183,
        0.0172,
        0.0202,
        0.0262,
        0.0302,
        0.035,
        0.0446,
        0.0663,
        0.0817,
        0.0651,
        0.05,
        0.0493,
        0.0646,
        0.316,
        0.738,
        0.769,
        0.685,
        0.587,
        0.48,
        0.371,
        0.286,
        0.211,
        0.128,
        0.0584,
        0.0213,
        0.0101
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone 11",
        "source_url": "https://docs.google.com/uc?export=download&id=1d_lhS5r2uW3JuFV58Bn93hjtV_RLPQoV"
      },
      "uncertainty": null,
      "values": [
        0.0246,
        0.0149,
        0.0158,
        0.0214,
        0.0324,
        0.0377,
        0.0472,
        0.148,
        0.433,
        0.686,
        0.846,
        0.932,
        0.97,
        1,
        0.997,
        0.952,
        0.883,
        0.79,
        0.681,
        0.535,
        0.38,
        0.236,
        0.151,
        0.102,
        0.0714,
        0.0526,
        0.0413,
        0.0317,
        0.0213,
        0.0126,
        0.00904
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone 11",
        "source_url": "https://docs.google.com/uc?export=download&id=1d_lhS5r2uW3JuFV58Bn93hjtV_RLPQoV"
      },
      "uncertainty": null,
      "values": [
        0.025,
        0.0383,
        0.121,
        0.296,
        0.447,
        0.55,
        0.599,
        0.615,
        0.597,
        0.57,
        0.468,
        0.355,
        0.239,
        0.168,
        0.131,
        0.0925,
        0.0651,
        0.0488,
        0.0434,
        0.0399,
        0.0342,
        0.0279,
        0.0241,
        0.0224,
        0.0221,
        0.0217,
        0.0206,
        0.0161,
        0.00949,
        0.00509,
        0.0038
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-04-fd0e228b11",
  "id": "ohtera2021-ohtera-txt-04-fd0e228b11",
  "kind": "camera",
  "label": "Apple iPhone 11 · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Apple",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "iPhone 11",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-04",
    "generational_ambiguity": null,
    "profile_prefix": "ohtera2021:ohtera-txt-04",
    "source_asset_id": "ohtera-txt-04",
    "source_asset_sha256": "d29a5b62b7015c2f246236d8e2a495ff3c4f1a51512bd60ff8f5cbade9a38bf2",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}
