  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone 12 Pro MAX (Normal lens)",
        "source_url": "https://docs.google.com/uc?export=download&id=1dSuouS7o-7DPx_EgXkNyUijngSVYY8dj"
      },
      "uncertainty": null,
      "values": [
        0.0221,
        0.0206,
        0.0282,
        0.0293,
        0.0266,
        0.0214,
        0.0195,
        0.0221,
        0.0272,
        0.0288,
        0.0326,
        0.0416,
        0.0627,
        0.0792,
        0.0612,
        0.0459,
        0.0459,
        0.0602,
        0.322,
        0.756,
        0.774,
        0.687,
        0.592,
        0.484,
        0.374,
        0.293,
        0.216,
        0.134,
        0.064,
        0.0237,
        0.0126
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone 12 Pro MAX (Normal lens)",
        "source_url": "https://docs.google.com/uc?export=download&id=1dSuouS7o-7DPx_EgXkNyUijngSVYY8dj"
      },
      "uncertainty": null,
      "values": [
        0.0353,
        0.026,
        0.0296,
        0.031,
        0.0399,
        0.0435,
        0.0504,
        0.157,
        0.465,
        0.693,
        0.848,
        0.948,
        0.974,
        1,
        0.997,
        0.956,
        0.893,
        0.808,
        0.712,
        0.555,
        0.399,
        0.253,
        0.166,
        0.114,
        0.0805,
        0.0603,
        0.0474,
        0.0373,
        0.0264,
        0.0163,
        0.0127
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "iPhone 12 Pro MAX (Normal lens)",
        "source_url": "https://docs.google.com/uc?export=download&id=1dSuouS7o-7DPx_EgXkNyUijngSVYY8dj"
      },
      "uncertainty": null,
      "values": [
        0.0318,
        0.101,
        0.271,
        0.44,
        0.526,
        0.599,
        0.635,
        0.66,
        0.637,
        0.576,
        0.476,
        0.363,
        0.237,
        0.167,
        0.131,
        0.0918,
        0.0632,
        0.0473,
        0.0419,
        0.036,
        0.03,
        0.024,
        0.0208,
        0.0194,
        0.0195,
        0.0198,
        0.0188,
        0.0151,
        0.00989,
        0.00571,
        0.00442
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-05-4a8ea38768",
  "id": "ohtera2021-ohtera-txt-05-4a8ea38768",
  "kind": "camera",
  "label": "Apple iPhone 12 Pro MAX (Normal lens) · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Apple",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "iPhone 12 Pro MAX (Normal lens)",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-05",
    "generational_ambiguity": null,
    "profile_prefix": "ohtera2021:ohtera-txt-05",
    "source_asset_id": "ohtera-txt-05",
    "source_asset_sha256": "9bf20d601f38cebb55048c4a0d5135071b5d1651b732f5c03bb68beb98ebc30a",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}