{
  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "P10 lite",
        "source_url": "https://docs.google.com/uc?export=download&id=1e9fOiYhpaqMh3e3LfD6X_ozSfX815nMN"
      },
      "uncertainty": null,
      "values": [
        0.0176,
        0.0329,
        0.0348,
        0.0265,
        0.0215,
        0.0164,
        0.0142,
        0.0167,
        0.0228,
        0.0253,
        0.0295,
        0.0385,
        0.0583,
        0.0704,
        0.054,
        0.0399,
        0.0395,
        0.0576,
        0.291,
        0.663,
        0.721,
        0.646,
        0.556,
        0.491,
        0.415,
        0.342,
        0.259,
        0.165,
        0.0761,
        0.0243,
        0.00882
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "P10 lite",
        "source_url": "https://docs.google.com/uc?export=download&id=1e9fOiYhpaqMh3e3LfD6X_ozSfX815nMN"
      },
      "uncertainty": null,
      "values": [
        0.0176,
        0.0232,
        0.0248,
        0.0211,
        0.0268,
        0.0301,
        0.0384,
        0.141,
        0.485,
        0.788,
        0.933,
        0.983,
        1,
        0.988,
        0.957,
        0.9,
        0.821,
        0.736,
        0.637,
        0.504,
        0.369,
        0.231,
        0.142,
        0.102,
        0.0771,
        0.0596,
        0.0465,
        0.0356,
        0.0233,
        0.0123,
        0.00846
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "P10 lite",
        "source_url": "https://docs.google.com/uc?export=download&id=1e9fOiYhpaqMh3e3LfD6X_ozSfX815nMN"
      },
      "uncertainty": null,
      "values": [
        0.0728,
        0.288,
        0.475,
        0.572,
        0.66,
        0.728,
        0.758,
        0.748,
        0.71,
        0.616,
        0.482,
        0.341,
        0.217,
        0.147,
        0.11,
        0.0787,
        0.0556,
        0.0446,
        0.0409,
        0.038,
        0.0329,
        0.0249,
        0.0207,
        0.0199,
        0.0202,
        0.0208,
        0.02,
        0.0167,
        0.0109,
        0.00635,
        0.00543
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-06-4063280ea2",
  "id": "ohtera2021-ohtera-txt-06-4063280ea2",
  "kind": "camera",
  "label": "HUAWEI P10 lite · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Huawei",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "P10 lite",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-06",
    "generational_ambiguity": null,
    "profile_prefix": "ohtera2021:ohtera-txt-06",
    "source_asset_id": "ohtera-txt-06",
    "source_asset_sha256": "dd824e2a26a7a6d2d1111172068c99ebac1dcedfaf1f474ccfa60f38bbc89915",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}
