  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "nova lite 2",
        "source_url": "https://docs.google.com/uc?export=download&id=1eD_Hp2K1Ajvr_16CERQipX0pZOB5SXJ3"
      },
      "uncertainty": null,
      "values": [
        0.011,
        0.013,
        0.0163,
        0.0157,
        0.0144,
        0.0126,
        0.0121,
        0.0175,
        0.0316,
        0.044,
        0.0551,
        0.0671,
        0.0862,
        0.099,
        0.0916,
        0.0868,
        0.0898,
        0.107,
        0.321,
        0.671,
        0.683,
        0.593,
        0.498,
        0.429,
        0.352,
        0.293,
        0.23,
        0.168,
        0.0908,
        0.0315,
        0.0102
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "nova lite 2",
        "source_url": "https://docs.google.com/uc?export=download&id=1eD_Hp2K1Ajvr_16CERQipX0pZOB5SXJ3"
      },
      "uncertainty": null,
      "values": [
        0.0149,
        0.019,
        0.0282,
        0.0314,
        0.0445,
        0.0546,
        0.0743,
        0.221,
        0.583,
        0.841,
        0.959,
        0.992,
        1,
        0.997,
        0.957,
        0.882,
        0.797,
        0.695,
        0.6,
        0.498,
        0.374,
        0.247,
        0.163,
        0.123,
        0.097,
        0.0807,
        0.0686,
        0.0589,
        0.0403,
        0.0192,
        0.01
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "nova lite 2",
        "source_url": "https://docs.google.com/uc?export=download&id=1eD_Hp2K1Ajvr_16CERQipX0pZOB5SXJ3"
      },
      "uncertainty": null,
      "values": [
        0.0203,
        0.123,
        0.302,
        0.444,
        0.559,
        0.657,
        0.682,
        0.7,
        0.686,
        0.62,
        0.528,
        0.414,
        0.289,
        0.216,
        0.178,
        0.145,
        0.116,
        0.0983,
        0.0912,
        0.0856,
        0.0725,
        0.0565,
        0.045,
        0.0408,
        0.0391,
        0.0387,
        0.0364,
        0.0312,
        0.0202,
        0.0095,
        0.00552
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-07-7493bd3bc8",
  "id": "ohtera2021-ohtera-txt-07-7493bd3bc8",
  "kind": "camera",
  "label": "HUAWEI nova lite 2 · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Huawei",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "nova lite 2",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-07",
    "generational_ambiguity": null,
    "profile_prefix": "ohtera2021:ohtera-txt-07",
    "source_asset_id": "ohtera-txt-07",
    "source_asset_sha256": "4a3fb2c3d3cd21d56e3781c165e67e1dff62cc6540f8d727a82378e70bd122f4",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}