  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Galaxy S9",
        "source_url": "https://docs.google.com/uc?export=download&id=1dg-jcll6Pi4qIJR6LDq6u0gOBceMWHND"
      },
      "uncertainty": null,
      "values": [
        0.0286,
        0.0259,
        0.0381,
        0.0321,
        0.0295,
        0.0231,
        0.0209,
        0.0245,
        0.033,
        0.0372,
        0.0421,
        0.0534,
        0.0759,
        0.0919,
        0.0765,
        0.0624,
        0.0632,
        0.0767,
        0.334,
        0.812,
        0.824,
        0.765,
        0.685,
        0.598,
        0.478,
        0.363,
        0.281,
        0.208,
        0.117,
        0.0388,
        0.0135
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Galaxy S9",
        "source_url": "https://docs.google.com/uc?export=download&id=1dg-jcll6Pi4qIJR6LDq6u0gOBceMWHND"
      },
      "uncertainty": null,
      "values": [
        0.04,
        0.027,
        0.0375,
        0.0341,
        0.0448,
        0.0463,
        0.0531,
        0.159,
        0.478,
        0.719,
        0.87,
        0.963,
        0.996,
        1,
        0.992,
        0.959,
        0.911,
        0.816,
        0.716,
        0.582,
        0.413,
        0.272,
        0.186,
        0.136,
        0.1,
        0.0735,
        0.0601,
        0.0544,
        0.0422,
        0.0228,
        0.013
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Galaxy S9",
        "source_url": "https://docs.google.com/uc?export=download&id=1dg-jcll6Pi4qIJR6LDq6u0gOBceMWHND"
      },
      "uncertainty": null,
      "values": [
        0.0458,
        0.155,
        0.365,
        0.455,
        0.545,
        0.605,
        0.63,
        0.667,
        0.677,
        0.626,
        0.524,
        0.42,
        0.29,
        0.207,
        0.171,
        0.128,
        0.0957,
        0.0751,
        0.0696,
        0.0652,
        0.0544,
        0.0455,
        0.0401,
        0.0387,
        0.0383,
        0.0368,
        0.0358,
        0.0327,
        0.0226,
        0.0102,
        0.00535
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-09-e2bc5dcfb3",
  "id": "ohtera2021-ohtera-txt-09-e2bc5dcfb3",
  "kind": "camera",
  "label": "Samsung Galaxy S9 · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Samsung",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "Galaxy S9",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-09",
    "generational_ambiguity": null,
    "profile_prefix": "ohtera2021:ohtera-txt-09",
    "source_asset_id": "ohtera-txt-09",
    "source_asset_sha256": "94451ead40f777cc2f1c5464c4e97796840831b98b5bb64c654f69a87aa3fd94",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}