  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Galaxy S20",
        "source_url": "https://docs.google.com/uc?export=download&id=1cy7QOxYX0wyuasg2Sqk8bXrPHYSqCvbP"
      },
      "uncertainty": null,
      "values": [
        0.0189,
        0.0234,
        0.0278,
        0.0253,
        0.0222,
        0.0177,
        0.0163,
        0.0188,
        0.024,
        0.0264,
        0.0307,
        0.0397,
        0.0602,
        0.0738,
        0.0609,
        0.0487,
        0.0493,
        0.0661,
        0.335,
        0.78,
        0.83,
        0.768,
        0.687,
        0.606,
        0.488,
        0.378,
        0.287,
        0.201,
        0.114,
        0.0396,
        0.0133
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Galaxy S20",
        "source_url": "https://docs.google.com/uc?export=download&id=1cy7QOxYX0wyuasg2Sqk8bXrPHYSqCvbP"
      },
      "uncertainty": null,
      "values": [
        0.0265,
        0.0254,
        0.029,
        0.0291,
        0.0373,
        0.0415,
        0.0514,
        0.158,
        0.454,
        0.681,
        0.847,
        0.938,
        0.983,
        0.993,
        1,
        0.967,
        0.903,
        0.814,
        0.732,
        0.587,
        0.433,
        0.282,
        0.188,
        0.135,
        0.0972,
        0.072,
        0.0581,
        0.0504,
        0.0388,
        0.0203,
        0.0106
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Galaxy S20",
        "source_url": "https://docs.google.com/uc?export=download&id=1cy7QOxYX0wyuasg2Sqk8bXrPHYSqCvbP"
      },
      "uncertainty": null,
      "values": [
        0.0393,
        0.165,
        0.314,
        0.435,
        0.511,
        0.583,
        0.62,
        0.652,
        0.65,
        0.607,
        0.52,
        0.406,
        0.285,
        0.204,
        0.165,
        0.12,
        0.0859,
        0.065,
        0.0587,
        0.0517,
        0.0439,
        0.0361,
        0.0319,
        0.0314,
        0.0321,
        0.0322,
        0.0316,
        0.0282,
        0.0198,
        0.00896,
        0.00434
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-11-10f0f22d4c",
  "id": "ohtera2021-ohtera-txt-11-10f0f22d4c",
  "kind": "camera",
  "label": "Samsung Galaxy S20 · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Samsung",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "Galaxy S20",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-11",
    "generational_ambiguity": null,
    "profile_prefix": "ohtera2021:ohtera-txt-11",
    "source_asset_id": "ohtera-txt-11",
    "source_asset_sha256": "93413d9522abd976f61a47f76b3a2ff84c70133bd96fe933df43b0b76e921402",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}