  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "AQUOS sense3 lite",
        "source_url": "https://docs.google.com/uc?export=download&id=1dDt17AZR1-poF65stGrQzLscWGkpAaLR"
      },
      "uncertainty": null,
      "values": [
        0.0105,
        0.00904,
        0.026,
        0.032,
        0.0266,
        0.0212,
        0.018,
        0.0203,
        0.0253,
        0.0271,
        0.0304,
        0.0388,
        0.0569,
        0.0718,
        0.0573,
        0.0426,
        0.0416,
        0.0549,
        0.248,
        0.672,
        0.749,
        0.691,
        0.617,
        0.548,
        0.478,
        0.418,
        0.368,
        0.309,
        0.2,
        0.088,
        0.0245
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "AQUOS sense3 lite",
        "source_url": "https://docs.google.com/uc?export=download&id=1dDt17AZR1-poF65stGrQzLscWGkpAaLR"
      },
      "uncertainty": null,
      "values": [
        0.0145,
        0.0118,
        0.0243,
        0.0302,
        0.0387,
        0.0444,
        0.0517,
        0.149,
        0.455,
        0.763,
        0.915,
        0.972,
        0.995,
        1,
        0.977,
        0.928,
        0.87,
        0.783,
        0.673,
        0.549,
        0.398,
        0.258,
        0.165,
        0.119,
        0.0933,
        0.0766,
        0.068,
        0.0663,
        0.0561,
        0.0344,
        0.0148
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "AQUOS sense3 lite",
        "source_url": "https://docs.google.com/uc?export=download&id=1dDt17AZR1-poF65stGrQzLscWGkpAaLR"
      },
      "uncertainty": null,
      "values": [
        0.011,
        0.0386,
        0.311,
        0.549,
        0.665,
        0.725,
        0.741,
        0.743,
        0.706,
        0.62,
        0.499,
        0.36,
        0.24,
        0.167,
        0.131,
        0.0988,
        0.0718,
        0.0572,
        0.0507,
        0.0464,
        0.0386,
        0.0305,
        0.0252,
        0.0236,
        0.0244,
        0.0269,
        0.0301,
        0.0316,
        0.0251,
        0.0137,
        0.00619
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-12-f7fd7e3830",
  "id": "ohtera2021-ohtera-txt-12-f7fd7e3830",
  "kind": "camera",
  "label": "SHARP AQUOS sense3 lite · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Sharp",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "AQUOS sense3 lite",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-12",
    "generational_ambiguity": null,
    "profile_prefix": "ohtera2021:ohtera-txt-12",
    "source_asset_id": "ohtera-txt-12",
    "source_asset_sha256": "3081383b012faf263bf17b2b4f4175b414b36b75374f4b9e3e9ff0c911714751",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}