  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "AQUOS R5G",
        "source_url": "https://docs.google.com/uc?export=download&id=1dJ3bJC-T13G4Vz6jF7vuuhLfQTWZKxno"
      },
      "uncertainty": null,
      "values": [
        0.0206,
        0.0249,
        0.0328,
        0.0305,
        0.0268,
        0.0215,
        0.0196,
        0.0231,
        0.0315,
        0.0357,
        0.0421,
        0.0529,
        0.0745,
        0.0883,
        0.0736,
        0.0626,
        0.0632,
        0.0816,
        0.338,
        0.774,
        0.798,
        0.736,
        0.662,
        0.585,
        0.506,
        0.442,
        0.369,
        0.273,
        0.158,
        0.0607,
        0.0226
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "AQUOS R5G",
        "source_url": "https://docs.google.com/uc?export=download&id=1dJ3bJC-T13G4Vz6jF7vuuhLfQTWZKxno"
      },
      "uncertainty": null,
      "values": [
        0.028,
        0.0275,
        0.0351,
        0.0363,
        0.047,
        0.0525,
        0.0635,
        0.184,
        0.501,
        0.732,
        0.891,
        0.972,
        1,
        0.994,
        0.974,
        0.956,
        0.89,
        0.806,
        0.716,
        0.58,
        0.419,
        0.279,
        0.193,
        0.142,
        0.112,
        0.0924,
        0.08,
        0.0707,
        0.0539,
        0.0286,
        0.0149
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "AQUOS R5G",
        "source_url": "https://docs.google.com/uc?export=download&id=1dJ3bJC-T13G4Vz6jF7vuuhLfQTWZKxno"
      },
      "uncertainty": null,
      "values": [
        0.0464,
        0.184,
        0.384,
        0.526,
        0.621,
        0.694,
        0.721,
        0.725,
        0.708,
        0.642,
        0.54,
        0.42,
        0.295,
        0.215,
        0.174,
        0.133,
        0.0984,
        0.0781,
        0.0714,
        0.065,
        0.0544,
        0.0451,
        0.0397,
        0.0387,
        0.0411,
        0.0446,
        0.0464,
        0.0419,
        0.0289,
        0.0135,
        0.00652
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-13-5b63607817",
  "id": "ohtera2021-ohtera-txt-13-5b63607817",
  "kind": "camera",
  "label": "SHARP AQUOS R5G · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Sharp",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "AQUOS R5G",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-13",
    "generational_ambiguity": null,
    "profile_prefix": "ohtera2021:ohtera-txt-13",
    "source_asset_id": "ohtera-txt-13",
    "source_asset_sha256": "8aa9b80be56918af91ef697b9f9f210be6b0d824058816fb23f399a489bff10c",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}