{
  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Mi Mix 2s",
        "source_url": "https://docs.google.com/uc?export=download&id=1dJoDD-39TremS1thPLJVjxB038FwRG0E"
      },
      "uncertainty": null,
      "values": [
        0.0183,
        0.0198,
        0.0347,
        0.0319,
        0.0278,
        0.0216,
        0.0191,
        0.0221,
        0.0282,
        0.0304,
        0.0353,
        0.0446,
        0.067,
        0.0829,
        0.065,
        0.0486,
        0.0491,
        0.0656,
        0.324,
        0.743,
        0.764,
        0.687,
        0.613,
        0.542,
        0.475,
        0.407,
        0.343,
        0.262,
        0.144,
        0.0434,
        0.0163
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Mi Mix 2s",
        "source_url": "https://docs.google.com/uc?export=download&id=1dJoDD-39TremS1thPLJVjxB038FwRG0E"
      },
      "uncertainty": null,
      "values": [
        0.0259,
        0.0218,
        0.0333,
        0.0315,
        0.0405,
        0.0442,
        0.0528,
        0.168,
        0.481,
        0.697,
        0.857,
        0.943,
        0.981,
        1,
        0.989,
        0.936,
        0.879,
        0.78,
        0.679,
        0.538,
        0.389,
        0.25,
        0.17,
        0.124,
        0.0961,
        0.077,
        0.067,
        0.0621,
        0.0462,
        0.0211,
        0.0117
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Mi Mix 2s",
        "source_url": "https://docs.google.com/uc?export=download&id=1dJoDD-39TremS1thPLJVjxB038FwRG0E"
      },
      "uncertainty": null,
      "values": [
        0.0352,
        0.128,
        0.476,
        0.511,
        0.603,
        0.664,
        0.683,
        0.704,
        0.681,
        0.615,
        0.526,
        0.408,
        0.286,
        0.209,
        0.167,
        0.12,
        0.0861,
        0.0638,
        0.0557,
        0.0488,
        0.0408,
        0.0334,
        0.0302,
        0.0304,
        0.034,
        0.0372,
        0.0395,
        0.037,
        0.0245,
        0.00948,
        0.00482
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-14-c6aa51798c",
  "id": "ohtera2021-ohtera-txt-14-c6aa51798c",
  "kind": "camera",
  "label": "Xiaomi Mi Mix 2s · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Xiaomi",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "Mi Mix 2s",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-14",
    "generational_ambiguity": null,
    "profile_prefix": "ohtera2021:ohtera-txt-14",
    "source_asset_id": "ohtera-txt-14",
    "source_asset_sha256": "19197915fd248e231a02ffa94180ac84fca8e6c4099b3d4159bb67c1a7647246",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}
