  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Redmi Note 9S",
        "source_url": "https://docs.google.com/uc?export=download&id=1dyVNc8XG8BAACwSrOVZpq73-T8MC4ZXR"
      },
      "uncertainty": null,
      "values": [
        0.0294,
        0.0312,
        0.039,
        0.0382,
        0.0368,
        0.0342,
        0.0349,
        0.0402,
        0.0484,
        0.055,
        0.0669,
        0.0833,
        0.114,
        0.134,
        0.116,
        0.101,
        0.105,
        0.132,
        0.43,
        0.903,
        0.938,
        0.849,
        0.768,
        0.656,
        0.518,
        0.402,
        0.31,
        0.225,
        0.128,
        0.0432,
        0.0149
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Redmi Note 9S",
        "source_url": "https://docs.google.com/uc?export=download&id=1dyVNc8XG8BAACwSrOVZpq73-T8MC4ZXR"
      },
      "uncertainty": null,
      "values": [
        0.0336,
        0.0366,
        0.0531,
        0.0568,
        0.0688,
        0.107,
        0.112,
        0.125,
        0.286,
        0.59,
        0.873,
        0.966,
        1,
        1,
        0.976,
        0.952,
        0.902,
        0.83,
        0.725,
        0.584,
        0.445,
        0.301,
        0.208,
        0.142,
        0.0999,
        0.0749,
        0.059,
        0.0492,
        0.0374,
        0.0195,
        0.0111
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Redmi Note 9S",
        "source_url": "https://docs.google.com/uc?export=download&id=1dyVNc8XG8BAACwSrOVZpq73-T8MC4ZXR"
      },
      "uncertainty": null,
      "values": [
        0.0433,
        0.182,
        0.339,
        0.444,
        0.516,
        0.577,
        0.618,
        0.641,
        0.617,
        0.553,
        0.464,
        0.361,
        0.261,
        0.201,
        0.17,
        0.139,
        0.115,
        0.103,
        0.0989,
        0.0931,
        0.0855,
        0.0744,
        0.0678,
        0.0628,
        0.0594,
        0.0559,
        0.0513,
        0.0431,
        0.0284,
        0.0121,
        0.00672
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-15-8e8971c6b8",
  "id": "ohtera2021-ohtera-txt-15-8e8971c6b8",
  "kind": "camera",
  "label": "Xiaomi Redmi Note 9S · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Xiaomi",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "Redmi Note 9S",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-15",
    "generational_ambiguity": null,
    "profile_prefix": "ohtera2021:ohtera-txt-15",
    "source_asset_id": "ohtera-txt-15",
    "source_asset_sha256": "bbd1b57d07313798a89d9211f2681f2f2add2725b7fb2ff4110889036f0bd4df",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}