  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Xperia 5 II",
        "source_url": "https://docs.google.com/uc?export=download&id=1dp8P_EShk1o2aBBxDFhfk-8GKACbKD-q"
      },
      "uncertainty": null,
      "values": [
        0.0179,
        0.0272,
        0.0277,
        0.0232,
        0.0202,
        0.0162,
        0.0149,
        0.0178,
        0.0232,
        0.0256,
        0.0295,
        0.0382,
        0.06,
        0.0744,
        0.0598,
        0.0468,
        0.0486,
        0.0676,
        0.348,
        0.805,
        0.849,
        0.794,
        0.713,
        0.628,
        0.499,
        0.384,
        0.291,
        0.21,
        0.116,
        0.0365,
        0.0107
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Xperia 5 II",
        "source_url": "https://docs.google.com/uc?export=download&id=1dp8P_EShk1o2aBBxDFhfk-8GKACbKD-q"
      },
      "uncertainty": null,
      "values": [
        0.0228,
        0.0259,
        0.027,
        0.0247,
        0.0321,
        0.036,
        0.0444,
        0.153,
        0.449,
        0.715,
        0.88,
        0.957,
        1,
        0.999,
        0.998,
        0.964,
        0.917,
        0.831,
        0.737,
        0.6,
        0.444,
        0.294,
        0.201,
        0.147,
        0.105,
        0.0772,
        0.0613,
        0.0534,
        0.0394,
        0.0184,
        0.00813
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Xperia 5 II",
        "source_url": "https://docs.google.com/uc?export=download&id=1dp8P_EShk1o2aBBxDFhfk-8GKACbKD-q"
      },
      "uncertainty": null,
      "values": [
        0.0606,
        0.222,
        0.343,
        0.435,
        0.517,
        0.596,
        0.648,
        0.694,
        0.697,
        0.641,
        0.534,
        0.411,
        0.288,
        0.205,
        0.166,
        0.121,
        0.0884,
        0.0679,
        0.0611,
        0.055,
        0.0469,
        0.039,
        0.0347,
        0.0343,
        0.0344,
        0.0339,
        0.0327,
        0.0291,
        0.0191,
        0.00693,
        0.003
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-17-7d7c27e206",
  "id": "ohtera2021-ohtera-txt-17-7d7c27e206",
  "kind": "camera",
  "label": "Sony Xperia 5 II · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Sony",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "Xperia 5 II",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-17",
    "generational_ambiguity": null,
    "profile_prefix": "ohtera2021:ohtera-txt-17",
    "source_asset_id": "ohtera-txt-17",
    "source_asset_sha256": "e64f7aa93f2640e78cfd449e2cda82d8776deba9f5cd586cf2f9e45966e15d2f",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}