{
  "category": "measured",
  "channels": [
    {
      "channel": "R",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Pixcel 4",
        "source_url": "https://docs.google.com/uc?export=download&id=1e4tAx3nOtvKMnzpj7-LsFzmN24Y1updp"
      },
      "uncertainty": null,
      "values": [
        0.0162,
        0.021,
        0.031,
        0.0292,
        0.0249,
        0.0198,
        0.0183,
        0.0216,
        0.0279,
        0.0306,
        0.0343,
        0.043,
        0.0626,
        0.0758,
        0.0608,
        0.0475,
        0.0477,
        0.0643,
        0.308,
        0.709,
        0.733,
        0.662,
        0.575,
        0.488,
        0.406,
        0.333,
        0.248,
        0.15,
        0.0588,
        0.0137,
        0.0073
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "G",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Pixcel 4",
        "source_url": "https://docs.google.com/uc?export=download&id=1e4tAx3nOtvKMnzpj7-LsFzmN24Y1updp"
      },
      "uncertainty": null,
      "values": [
        0.0252,
        0.0239,
        0.0318,
        0.033,
        0.0424,
        0.0477,
        0.0603,
        0.187,
        0.507,
        0.75,
        0.895,
        0.962,
        0.982,
        1,
        0.981,
        0.921,
        0.861,
        0.779,
        0.667,
        0.515,
        0.37,
        0.238,
        0.157,
        0.111,
        0.0833,
        0.065,
        0.0512,
        0.0385,
        0.0219,
        0.00985,
        0.0078
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    },
    {
      "channel": "B",
      "native_metadata": {
        "camera_sensor_mapping": "not asserted from TXT; paper's attributed claims are separate evidence",
        "citation": {
          "authors": [
            "Shoji Tominaga",
            "Shogo Nishi",
            "Ryo Ohtera"
          ],
          "doi": "10.3390/s21154985",
          "organization": "Kobe Institute of Computing and author affiliations in article",
          "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
          "year": 2021
        },
        "grid_evidence": {
          "section": "2.1",
          "sha256": "0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6",
          "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"
        },
        "measurement_summary": "paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system",
        "normalization": "unknown; values preserved verbatim",
        "original_source_label": "Pixcel 4",
        "source_url": "https://docs.google.com/uc?export=download&id=1e4tAx3nOtvKMnzpj7-LsFzmN24Y1updp"
      },
      "uncertainty": null,
      "values": [
        0.0399,
        0.16,
        0.37,
        0.513,
        0.584,
        0.664,
        0.715,
        0.737,
        0.71,
        0.648,
        0.524,
        0.4,
        0.274,
        0.198,
        0.158,
        0.113,
        0.0804,
        0.0612,
        0.0534,
        0.0462,
        0.0387,
        0.0315,
        0.0274,
        0.0264,
        0.028,
        0.0294,
        0.0281,
        0.0212,
        0.0105,
        0.00402,
        0.00316
      ],
      "wavelengths_nm": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ]
    }
  ],
  "configuration": {
    "camera_module": "as documented by source; details unavailable in TXT"
  },
  "entity_id": "ohtera2021-ohtera-txt-19-f199370111",
  "id": "ohtera2021-ohtera-txt-19-f199370111",
  "kind": "camera",
  "label": "Google Pixcel 4 · camera_module=\"as documented by source; details unavailable in TXT\"",
  "manufacturer": "Google",
  "method": {
    "dataset": "Ohtera2021",
    "source_category": "measured",
    "source_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1"
  },
  "model": "Pixcel 4",
  "provenance": {
    "dataset_camera_id": "ohtera2021:ohtera-txt-19",
    "generational_ambiguity": null,
    "profile_prefix": "ohtera2021:ohtera-txt-19",
    "source_asset_id": "ohtera-txt-19",
    "source_asset_sha256": "3bb81827498dd0298ad9dd11e0debc6f2183f321eb5fe02c5f9b0b9901587669",
    "source_id": "ohtera-2021"
  },
  "response_scope": "camera",
  "scale": "relative (source scale; not absolute QE)",
  "source": {
    "id": "ohtera-2021",
    "title": "Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras",
    "url": "https://ohlab.kic.ac.jp/index/mobilespec_database",
    "accessed_at": "2026-10-05T09:42:36.223687+00:00",
    "authors": [
      "Shoji Tominaga",
      "Shogo Nishi",
      "Ryo Ohtera"
    ],
    "organization": "Kobe Institute of Computing and author affiliations in article",
    "year": 2021,
    "license_status": "unknown",
    "observed_license": null,
    "downstream_reuse_grant": false,
    "measurement_method": "OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1",
    "scope": "camera"
  },
  "uncertainty": {
    "per_channel": {
      "B": null,
      "G": null,
      "R": null
    }
  },
  "units": "relative spectral sensitivity",
  "schema": "camera-spectra-public-research-profile-1"
}
