Sony Xperia 1 II

camera · measured · relative spectral sensitivity

Documented response scope: camera

Native channel samples

Each channel retains its source wavelength grid and values. The plot uses shared display axes; gaps and negative values remain visible. No normalization, interpolation, averaging, or resampling is applied.

Native response channels for Sony Xperia 1 IIEach channel uses its original wavelength grid. Gaps remain disconnected; values are shown without normalization or interpolation.RGB400 nm700 nm10
Native samples on a shared display axis: 400–700 nm, 0 to 1. Curves are not normalized, averaged, interpolated, or resampled.
  • R
  • G
  • B
Source, rights and technical details

Source and rights

Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras

Authors: Shoji Tominaga, Shogo Nishi, Ryo Ohtera

Organization: Kobe Institute of Computing and author affiliations in article

Year: 2021

Accessed:

License status: unknown

Publication is authorized by the project owner. This publication does not grant downstream reuse.

Have license information? Contact the project owner.

Source ID: ohtera-2021

Research details

Configuration
camera_module
as documented by source; details unavailable in TXT
Method
dataset
Ohtera2021
source_category
measured
source_method
OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1
Uncertainty
per_channel
{"B":null,"G":null,"R":null}
Provenance
dataset_camera_id
ohtera2021:ohtera-txt-16
profile_prefix
ohtera2021:ohtera-txt-16
source_asset_id
ohtera-txt-16
source_asset_sha256
3b5d3c6a82d908b9433c5fb6c0759b2c8f2ec02cad8fd32321c841bf9017e9aa
source_id
ohtera-2021

Channel metadata

R · 31 native samples
camera_sensor_mapping
not asserted from TXT; paper's attributed claims are separate evidence
citation
{"authors":["Shoji Tominaga","Shogo Nishi","Ryo Ohtera"],"doi":"10.3390/s21154985","organization":"Kobe Institute of Computing and author affiliations in article","title":"Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras","year":2021}
grid_evidence
{"section":"2.1","sha256":"0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6","url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"}
measurement_summary
paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system
normalization
unknown; values preserved verbatim
original_source_label
Xperia 1 II
source_url
https://docs.google.com/uc?export=download&id=1dr2EpZY-szOohEBiWGmql8vyPcUKXYUT
G · 31 native samples
camera_sensor_mapping
not asserted from TXT; paper's attributed claims are separate evidence
citation
{"authors":["Shoji Tominaga","Shogo Nishi","Ryo Ohtera"],"doi":"10.3390/s21154985","organization":"Kobe Institute of Computing and author affiliations in article","title":"Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras","year":2021}
grid_evidence
{"section":"2.1","sha256":"0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6","url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"}
measurement_summary
paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system
normalization
unknown; values preserved verbatim
original_source_label
Xperia 1 II
source_url
https://docs.google.com/uc?export=download&id=1dr2EpZY-szOohEBiWGmql8vyPcUKXYUT
B · 31 native samples
camera_sensor_mapping
not asserted from TXT; paper's attributed claims are separate evidence
citation
{"authors":["Shoji Tominaga","Shogo Nishi","Ryo Ohtera"],"doi":"10.3390/s21154985","organization":"Kobe Institute of Computing and author affiliations in article","title":"Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras","year":2021}
grid_evidence
{"section":"2.1","sha256":"0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6","url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"}
measurement_summary
paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system
normalization
unknown; values preserved verbatim
original_source_label
Xperia 1 II
source_url
https://docs.google.com/uc?export=download&id=1dr2EpZY-szOohEBiWGmql8vyPcUKXYUT