Teledyne e2v CCD77-00
Teledyne e2v CCD77-00 · sensor · digitized · percent QE
Documented response scope: as described by source
Native channel samples
Each channel retains its source wavelength grid and values. The plot uses shared display axes; gaps and negative values remain visible. No normalization, interpolation, averaging, or resampling is applied.
- mono
Source, rights and technical details
Source and rights
https://diffractionlimited.com/product/sbig-aluma-ccd77-00/ — basic midband coated graph trace
Authors: Diffraction Limited (manufacturer page; original graph author not stated)
Organization: Diffraction Limited (manufacturer page; original graph author not stated)
License status: unknown
Publication is authorized by the project owner. This publication does not grant downstream reuse.
Have license information? Contact the project owner.
Source ID: sbig-ccd77-00-basic-midband-coated
Research details
Configuration
- manufacturer
- Teledyne e2v
- mode
- mono
- model
- CCD77-00
Method
- axes
{"response_axis":[0,100],"wavelength_nm":[200,1100],"x_pixel":[40,664],"y_pixel":[701,8]}- image_sha256
- 4d30a2f4521772414c30de21ba1ed026424b6a2a93f37d194831726cbf7f0d60
- image_size_px
[677,735]- masked_label_rectangles_px
[[263,164,336,203],[393,69,453,109],[300,279,362,308]]- maximum_detected_trace_width_px
- 7
- method
- native RGB PNG decode; dark grid rows/columns masked; each named trace followed from an explicit seed; ties/discontinuities retained as null
- missing_samples
- 149
- raster_tolerance_nm
- 7.212
- raster_tolerance_response_axis_units
- 0.722
- sample_pixel_centres
[[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[231,101],[234,96],[null,null],[241,85],[245,80.5],[null,null],[null,null],[255,72],[258,71],[262,68.5],[265,67.5],[null,null],[272,64.5],[276,63.5],[279,62.5],[null,null],[null,null],[290,60.5],[293,60.5],[297,60.5],[300,60],[303,60],[null,null],[310,60.5],[314,61],[null,null],[321,62],[null,null],[328,64],[331,64.5],[335,65.5],[338,66.5],[342,67.5],[null,null],[349,71],[null,null],[355,75],[359,76],[null,null],[366,81.5],[369,83.5],[373,87],[null,null],[380,93],[383,95.5],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null],[null,null]]- sample_step_nm
- 5
- script
- scripts/research-intake-20261005/digitize-sbig-camera-graphs.py
- seed_trace_pixels
{"basic broadband coated":155,"basic midband coated":66,"basic uncoated":276}- seed_wavelength_nm
- 600
- working_image_sha256
- 4d30a2f4521772414c30de21ba1ed026424b6a2a93f37d194831726cbf7f0d60
Uncertainty
- Value
["Digitized from manufacturer-hosted raster; underlying numerical measurement data not provided.","Measurement author, instrument, conditions, and measurement uncertainty are not documented.","Sensor/coating curve is not a complete camera spectral response.","Only visibly distinguishable pixels were sampled; nulls retain gaps and ambiguous intersections."]
Provenance
- curve_id
- sbig-ccd77-00-basic-midband-coated
- source_asset_sha256
- 4d30a2f4521772414c30de21ba1ed026424b6a2a93f37d194831726cbf7f0d60
- verified_receipt_sha256
- 4d30a2f4521772414c30de21ba1ed026424b6a2a93f37d194831726cbf7f0d60
Channel metadata
mono · 181 native samples
- record_role
- new_digitized_reference