FUJIFILM GFX50S II
Response
- red (R)
- green (G)
- blue (B)
Astro mode
Emission-line overlay on the active single-profile plot. Values are the source's own native samples (or a labelled linear interpolation).
About this spectrum5 notes
- Warning: Response scope is unknown; do not interpret this response as a bare-sensor measurement. Dataset interpretation
- Warning: Physical configuration is not documented; the response cannot be assigned to a confirmed optical configuration. Dataset interpretation
- Warning: Estimated response; not a primary measurement. Sources and attribution
- Warning: Normalization is unknown; amplitude comparisons are not established. Dataset interpretation
- Warning: Uncertainty is not documented. Missing uncertainty does not mean zero uncertainty. Dataset interpretation
Source & details
- Source category: estimated
- Estimated response: not a primary measurement (e.g. diffraction-grating closed-form recovery, model prediction). Independent of profile_type and quality/confidence grades.
- Type: estimated
- Estimated response, not a direct measurement; quality and confidence are assessed separately.
- Quality: unassessed
- Quality has not been assessed; no grade is inferred. Canonical release: no per-leaf scientific-quality assessment is asserted; the source-side claim is preserved verbatim.
- Confidence: unassessed
- Confidence has not been assessed; no confidence level is inferred. Canonical release: no claim about the per-leaf measurement precision is asserted; the upstream 'as is' wording (where present) is preserved.
- Author
- Solomatov
- Source
- Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera' (link)
- Source category
estimated(estimated response; not a primary measurement)- Methodology
- Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera' — model output.
- As-is
- Samples rendered verbatim: no smoothing, no interpolation, no zero-padding, no gap bridging in the browser. Documented null sparse cells render as visible gaps.
- Optical configuration
cfg-prf-solomatov-pred-fujifilm-gfx-50s-ii-8b9eb57b8528(unknown) — unknown- Normalisation
- unknown (original: unknown)
- Response unit / scale
unknown/unknown- Sample count
- 31 samples from 400–700 nm, Δ 10 nm
- Profile ID
prf-solomatov-pred-fujifilm-gfx-50s-ii-8b9eb57b8528@1- Profile checksum
sha256:f16162c346149115…- Processing
- source_column=predicted-Fujifilm-GFX-50S-II.csv
- Scientific notes
- Canonical release: native grid and native R/G/B samples are preserved verbatim; sparse cells (wavelengths absent in the upstream CSV / JSON) are preserved as null; the parser never invents a value.
- Citation
- Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.
- Known limitations
- source_category=estimated
- permission_status is 'unknown' on the canonical License record (no independent operational clearance granted).
Graph tools
Inspect, zoom, export, and share the current chart. Native samples only — no interpolation, no averaging.
Channels
Zoom (nm)
Camera specifications
- Sensor type
- Unknown
- Sensor format
- Medium format
- Sensor size
- Unknown
- Effective megapixels
- Unknown
- Resolution
- Unknown
- Lens mount
- Fujifilm G
- Release year
- Unknown
Specification sources
Body specifications drawn from cited reference sources, distinct from the measured spectral response curves below.
Source: Dataset commit ef88b8381775c8c8c812c10cd02790a42dbdf757 Dataset: OpenProductData (unknown); Dataset commit 2f1be1deab50da7869fc5d23f481939803d845bf Dataset: Lensfun (CC BY-SA 3.0)
Also known as: Fujifilm GFX 50S II.
Data details
- Dataset version
recovered-2026-09-29-all-available-with-ie-202404- Manifest digest
8f960e18d6c9dbef…- Manifest schema
0.1.0-draft- Release kind
full- Linked profiles / sessions
- 1 profile revision
Raw samples (R/G/B at native wavelengths)
prf-solomatov-pred-fujifilm-gfx-50s-ii-8b9eb57b8528(revision 1)Raw samples for prf-solomatov-pred-fujifilm-gfx-50s-ii-8b9eb57b8528 (revision 1): R/G/B response at native wavelengths. λ (nm) R G B 400 0.002952309 0.0050065126 0.012917515 410 0.0067268405 0.008758146 0.030881422 420 0.006868496 0.017674584 0.071913965 430 0.000020178188 0.028825508 0.120160565 440 0.0000020656573 0.04204826 0.1531019 450 0.0055578793 0.052447148 0.17729358 460 0.014036573 0.06455901 0.19731033 470 0.022568176 0.085903384 0.20507905 480 0.03354777 0.11235373 0.19949277 490 0.032243498 0.1401805 0.17573866 500 0.025378311 0.17413741 0.13926022 510 0.017062685 0.21656479 0.10211708 520 0.007423057 0.24684517 0.0673097 530 0.000008767476 0.25768262 0.042339746 540 0.000019536643 0.2543459 0.030131388 550 0.0012063968 0.24126674 0.021696324 560 0.002735908 0.219851 0.019005127 570 0.055811007 0.18518193 0.020721128 580 0.15394895 0.14538133 0.021990797 590 0.20416377 0.10931545 0.017002968 600 0.20097533 0.08240378 0.009032018 610 0.18266405 0.06100156 0.0026001295 620 0.15811968 0.045933116 0.0010223689 630 0.13844185 0.032123204 0.0000063621974 640 0.120914705 0.0209602 0.000013486532 650 0.10090625 0.01122354 0.000009044039 660 0.081563644 0.0062450916 8.095292e-7 670 0.05758691 0.0016600059 0.0000013467007 680 0.0327121 0.00058970833 0.000012225717 690 0.013046483 0.0016453376 0.000006743783 700 0.009659058 0.00006130398 0.00008559695