LEICA X2

Response

Native RGB responseestimatedLEICA X2 · Solomatov GT collection
Hover or tap graph for values
  • red (R)
  • green (G)
  • blue (B)

Astro mode

Emission-line overlay on the active single-profile plot. Values are the source's own native samples (or a labelled linear interpolation).

About this spectrum5 notes
  • Warning: Response scope is unknown; do not interpret this response as a bare-sensor measurement. Dataset interpretation
  • Warning: Physical configuration is not documented; the response cannot be assigned to a confirmed optical configuration. Dataset interpretation
  • Warning: Estimated response; not a primary measurement. Sources and attribution
  • Warning: Normalization is unknown; amplitude comparisons are not established. Dataset interpretation
  • Warning: Uncertainty is not documented. Missing uncertainty does not mean zero uncertainty. Dataset interpretation
Source & details
Source category: estimated
Estimated response: not a primary measurement (e.g. diffraction-grating closed-form recovery, model prediction). Independent of profile_type and quality/confidence grades.
Type: estimated
Estimated response, not a direct measurement; quality and confidence are assessed separately.
Quality: unassessed
Quality has not been assessed; no grade is inferred. Canonical release: no per-leaf scientific-quality assessment is asserted; the source-side claim is preserved verbatim.
Confidence: unassessed
Confidence has not been assessed; no confidence level is inferred. Canonical release: no claim about the per-leaf measurement precision is asserted; the upstream 'as is' wording (where present) is preserved.
Author
Solomatov
Source
Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera' (link)
Source category
estimated (estimated response; not a primary measurement)
Methodology
Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera' — model output.
As-is
Samples rendered verbatim: no smoothing, no interpolation, no zero-padding, no gap bridging in the browser. Documented null sparse cells render as visible gaps.
Optical configuration
cfg-prf-solomatov-pred-leica-x2-a84d9e81d061 (unknown) — unknown
Normalisation
unknown (original: unknown)
Response unit / scale
unknown / unknown
Sample count
31 samples from 400–700 nm, Δ 10 nm
Profile ID
prf-solomatov-pred-leica-x2-a84d9e81d061@1
Profile checksum
sha256:5ee8ac203d02d86e…
Processing
source_column=predicted-LEICA-X2.csv
Scientific notes
Canonical release: native grid and native R/G/B samples are preserved verbatim; sparse cells (wavelengths absent in the upstream CSV / JSON) are preserved as null; the parser never invents a value.
Citation
Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.
Known limitations
  • source_category=estimated
  • permission_status is 'unknown' on the canonical License record (no independent operational clearance granted).

Graph tools

Inspect, zoom, export, and share the current chart. Native samples only — no interpolation, no averaging.

Channels
Zoom (nm)

Camera specifications

Sensor type
CMOS
Sensor format
Unknown
Sensor size
23.6 x 15.8 mm
Effective megapixels
16.2 MP
Resolution
Unknown
Lens mount
Unknown
Release year
2012
Specification sources

Body specifications drawn from cited reference sources, distinct from the measured spectral response curves below.

Source: Dataset commit 374a630bac7847f851b3746e82aa528262ef0b5c Dataset: CameraDatabase (unknown)

Data details
Dataset version
recovered-2026-09-29-all-available-with-ie-202404
Manifest digest
8f960e18d6c9dbef…
Manifest schema
0.1.0-draft
Release kind
full
Linked profiles / sessions
1 profile revision
Raw samples (R/G/B at native wavelengths)
  1. prf-solomatov-pred-leica-x2-a84d9e81d061 (revision 1)

    Raw samples for prf-solomatov-pred-leica-x2-a84d9e81d061 (revision 1): R/G/B response at native wavelengths.
    λ (nm)RGB
    4000.002848550.00465424270.014127675
    4100.00546560760.0082397130.0327167
    4200.00715865430.0171211680.075528435
    4300.000395780170.0292128860.12424848
    4400.00624355070.042478480.15889354
    4500.0113163530.052312630.18614101
    4600.0157588460.0655183640.20860489
    4700.0186599870.087321810.21850236
    4800.0238060970.1151936050.21527292
    4900.0212128740.145386430.18840772
    5000.0163454020.181535620.14771509
    5100.0114348940.224745870.10334429
    5200.0080892510.25456090.061984114
    5300.0013332220.265267340.031063676
    5400.0000022717870.260042250.017141752
    5500.000002201990.244338450.007877071
    5600.00621095770.21961440.00587715
    5700.0582537870.18363160.0074144583
    5800.139757710.14297930.0094220275
    5900.184167710.1057588460.007727168
    6000.179210750.076243110.00379531
    6100.164733290.052989040.0021543996
    6200.143331230.0384453350.0026833455
    6300.125621660.0262402450.00048764306
    6400.1080557260.017472620.000019473739
    6500.090786320.0102116763.063949e-7
    6600.072811140.0063649889.869774e-7
    6700.0512062650.00241602825.4108742e-8
    6800.0301447570.00164534770.0000032048742
    6900.0126298850.00138769520.000026971755
    7000.0086563830.0000377671930.00019063354