Olympus E-10

Response

Native RGB responseestimatedOlympus E 10 · Solomatov GT collection
Hover or tap graph for values
  • red (R)
  • green (G)
  • blue (B)

Astro mode

Emission-line overlay on the active single-profile plot. Values are the source's own native samples (or a labelled linear interpolation).

About this spectrum5 notes
  • Warning: Response scope is unknown; do not interpret this response as a bare-sensor measurement. Dataset interpretation
  • Warning: Physical configuration is not documented; the response cannot be assigned to a confirmed optical configuration. Dataset interpretation
  • Warning: Estimated response; not a primary measurement. Sources and attribution
  • Warning: Normalization is unknown; amplitude comparisons are not established. Dataset interpretation
  • Warning: Uncertainty is not documented. Missing uncertainty does not mean zero uncertainty. Dataset interpretation
Source & details
Source category: estimated
Estimated response: not a primary measurement (e.g. diffraction-grating closed-form recovery, model prediction). Independent of profile_type and quality/confidence grades.
Type: estimated
Estimated response, not a direct measurement; quality and confidence are assessed separately.
Quality: unassessed
Quality has not been assessed; no grade is inferred. Canonical release: no per-leaf scientific-quality assessment is asserted; the source-side claim is preserved verbatim.
Confidence: unassessed
Confidence has not been assessed; no confidence level is inferred. Canonical release: no claim about the per-leaf measurement precision is asserted; the upstream 'as is' wording (where present) is preserved.
Author
Solomatov
Source
Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera' (link)
Source category
estimated (estimated response; not a primary measurement)
Methodology
Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera' — model output.
As-is
Samples rendered verbatim: no smoothing, no interpolation, no zero-padding, no gap bridging in the browser. Documented null sparse cells render as visible gaps.
Optical configuration
cfg-prf-solomatov-pred-olympus-e-10-2cc2663a53ff (unknown) — unknown
Normalisation
unknown (original: unknown)
Response unit / scale
unknown / unknown
Sample count
31 samples from 400–700 nm, Δ 10 nm
Profile ID
prf-solomatov-pred-olympus-e-10-2cc2663a53ff@1
Profile checksum
sha256:3eb10f9ea8fc4437…
Processing
source_column=predicted-Olympus-E-10.csv
Scientific notes
Canonical release: native grid and native R/G/B samples are preserved verbatim; sparse cells (wavelengths absent in the upstream CSV / JSON) are preserved as null; the parser never invents a value.
Citation
Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.
Known limitations
  • source_category=estimated
  • permission_status is 'unknown' on the canonical License record (no independent operational clearance granted).

Graph tools

Inspect, zoom, export, and share the current chart. Native samples only — no interpolation, no averaging.

Channels
Zoom (nm)

Camera specifications

Sensor type
CCD
Sensor format
Unknown
Sensor size
Unknown
Effective megapixels
3.7 MP
Resolution
Unknown
Lens mount
Unknown
Release year
2000
Specification sources

Body specifications drawn from cited reference sources, distinct from the measured spectral response curves below.

Source: Dataset commit 374a630bac7847f851b3746e82aa528262ef0b5c Dataset: CameraDatabase (unknown)

Also known as: Olympus E 10.

Data details
Dataset version
recovered-2026-09-29-all-available-with-ie-202404
Manifest digest
8f960e18d6c9dbef…
Manifest schema
0.1.0-draft
Release kind
full
Linked profiles / sessions
1 profile revision
Raw samples (R/G/B at native wavelengths)
  1. prf-solomatov-pred-olympus-e-10-2cc2663a53ff (revision 1)

    Raw samples for prf-solomatov-pred-olympus-e-10-2cc2663a53ff (revision 1): R/G/B response at native wavelengths.
    λ (nm)RGB
    4000.0026320430.00435900870.0122948
    4100.00518457820.00712932460.02998205
    4200.00690719350.0128066240.070920646
    4300.0011090010.0210979170.12277933
    4400.00667409970.027528840.16170725
    4500.0096207610.0334548280.18954109
    4600.01253722050.0460682960.2106216
    4700.0132414180.07336190.21750101
    4800.0155244850.107721080.21178429
    4900.0150789210.142245680.18704376
    5000.0122186740.181462030.14994754
    5100.0105527680.226999490.111328036
    5200.0104874340.2575180.07557279
    5300.0059050290.268745120.04944148
    5400.0000285602960.264537250.03678684
    5500.000402182050.248378520.027229635
    5600.01110990250.223144680.022057088
    5700.067404410.184410770.01971974
    5800.147021840.139278920.018355953
    5900.187743320.09984630.0123344185
    6000.180396360.069537090.0027025926
    6100.161951810.0469738130.000025616431
    6200.139375630.0330699940.000018463417
    6300.119679270.0218380650.000006047291
    6400.1024332340.01246656850.0000028721024
    6500.084220320.00531608750.00074524264
    6600.065775770.0025565040.0025707784
    6700.04496830.00000141227620.0028700945
    6800.0254772060.0000103462840.0016982753
    6900.0096027880.0009700030.0002920393
    7000.0073612490.0000570875960.0008520932