Olympus OM-D E-M1 Mark II

Response

Native RGB responsemeasuredOlympus OM-D E-M1MII · Image Engineering 2024
Hover or tap graph for values
  • red (R)
  • green (G)
  • blue (B)

Astro mode

Emission-line overlay on the active single-profile plot. Values are the source's own native samples (or a labelled linear interpolation).

About this spectrum4 notes
  • Warning: Response scope is unknown; do not interpret this response as a bare-sensor measurement. Dataset interpretation
  • Warning: Physical configuration is not documented; the response cannot be assigned to a confirmed optical configuration. Dataset interpretation
  • Warning: Normalization is unknown; amplitude comparisons are not established. Dataset interpretation
  • Warning: Uncertainty is not documented. Missing uncertainty does not mean zero uncertainty. Dataset interpretation
Source & details
Source category: measured
Primary measurement: a direct laboratory observation (or community submission recorded as measured). Not a mirror, not an estimation.
Type: measured
Measured response; measurement alone does not establish quality or confidence.
Origin: Community
Community provenance; origin does not establish measurement type, quality or confidence.
Quality: unassessed
Quality has not been assessed; no grade is inferred. Canonical release: no per-leaf scientific-quality assessment is asserted; the source-side claim is preserved verbatim.
Confidence: unassessed
Confidence has not been assessed; no confidence level is inferred. Canonical release: no claim about the per-leaf measurement precision is asserted; the upstream 'as is' wording (where present) is preserved.
Author
Image Engineering GmbH & Co. KG
Source
Image Engineering spectral sensitivities workbook (April 2024) (link)
Source category
measured (primary measurement; not a mirror or estimation)
As-is
Samples rendered verbatim: no smoothing, no interpolation, no zero-padding, no gap bridging in the browser. Documented null sparse cells render as visible gaps.
Optical configuration
cfg-prf-ie2024-olympus-om-d-e-m1mii-df-occ37 (unknown) — unknown
Normalisation
unknown (original: unknown)
Response unit / scale
unknown / unknown
Sample count
135 samples from 380–1050 nm, Δ 5 nm
Profile ID
prf-ie2024-olympus-om-d-e-m1mii-df-occ37@1
Profile checksum
sha256:ea396ae2c18b6771…
Processing
source_column=DF
Scientific notes
Canonical release: native grid and native R/G/B samples are preserved verbatim; sparse cells (wavelengths absent in the upstream CSV / JSON) are preserved as null; the parser never invents a value.
Citation
Image Engineering GmbH & Co. KG, Spectral sensitivities workbook (April 2024).
Known limitations
  • source_category=measured
  • permission_status is 'unknown' on the canonical License record (no independent operational clearance granted).

Compare measurements

Overlay up to 4 measurements on the same chart. Each path uses its native grid; no interpolation, no averaging, no merge.

Graph tools

Inspect, zoom, export, and share the current chart. Native samples only — no interpolation, no averaging.

Channels
Zoom (nm)

Also known as: Olympus E-M1 Mark II · Olympus E-M1MII · Olympus OM-D E-M1MII · Olympus E M1 Mark II.

Data details
Dataset version
recovered-2026-09-29-all-available-with-ie-202404
Manifest digest
8f960e18d6c9dbef…
Manifest schema
0.1.0-draft
Release kind
full
Linked profiles / sessions
2 profile revisions
Raw samples (R/G/B at native wavelengths)
  1. prf-ie2024-olympus-om-d-e-m1mii-df-occ37 (revision 1)

    Raw samples for prf-ie2024-olympus-om-d-e-m1mii-df-occ37 (revision 1): R/G/B response at native wavelengths.
    λ (nm)RGB
    3800.01591134170.05363232610.0885105061
    3850.01231199810.03650414420.0523506623
    3900.00871265450.01937596230.0161908184
    3950.01724749050.02712496370.0554508653
    4000.02578232650.03487396510.0947109123
    4050.03115610620.04444194520.1502764512
    4100.03573962180.05446466990.209918363
    4150.03513757860.06358659320.2500639328
    4200.03453553540.07270851660.2902095027
    4250.03337141140.0845761130.3326849059
    4300.03183256680.09827415820.3767135312
    4350.03185110930.12027649780.4389477565
    4400.03186965170.14227883730.5011819819
    4450.03027450710.1636580850.546504228
    4500.02879962920.18602348310.5821267625
    4550.02941950490.21295657460.5958624297
    4600.03003938070.2398896660.6095980969
    4650.03142846670.28022891050.6107311077
    4700.03281755260.3205681550.6118641184
    4750.03594804730.36991262370.5972507547
    4800.03907854190.41925709250.5826373909
    4850.03943714050.4611698420.5508756489
    4900.03979573920.50308259140.5191139068
    4950.04244786830.57439011220.4723152805
    5000.04509999740.6456976330.4255166542
    5050.05073126990.70482386640.371695491
    5100.05710732820.7609047780.3161186936
    5150.0714834210.82411121990.258991099
    5200.08613511560.88186850680.2103378676
    5250.09820020.9287799870.17497773
    5300.11026528430.97569146720.1396175924
    5350.09468446740.99139826260.1204757607
    5400.080002669810.1017853297
    5450.06891694930.98018150530.0849005018
    5500.05783122880.96036301070.0680156738
    5550.05785103410.93605859790.0557235364
    5600.05787083940.91175418520.043431399
    5650.07359892340.8563342370.035337551
    5700.0932540770.79313540490.0282932754
    5750.25863256290.74135925410.0257355142
    5800.44995320680.68753275070.0242322767
    5850.62554083840.62634721270.0226283814
    5900.80112846990.56516167470.0210244861
    5950.79327570670.49479792450.0192119756
    6000.78542294350.42443417420.0173994651
    6050.75530135240.35025602210.015390324
    6100.69177651950.27035626720.0130862369
    6150.65754014320.21389039030.0118993851
    6200.64282940460.17304709880.0114573568
    6250.5989188610.14523724590.0116911549
    6300.55500831730.11742739290.011924953
    6350.53468705760.10641777610.0128243389
    6400.5143657980.09540815930.0137237249
    6450.46690265450.08233312360.0145326582
    6500.41265404010.0687417330.0153189783
    6550.33167048840.05385885120.0141791784
    6600.23286364520.03811497510.0117552985
    6650.16068543020.02803103810.0087707979
    6700.09632278750.01894061070.0059934363
    6750.06322243410.01382422210.0040446307
    6800.03832678870.00977106330.0025149377
    6850.02573820570.0073127490.0016139137
    6900.0146954660.00509680320.0008425803
    6950.00983609980.00385033110.0005900094
    7000.00572407340.00279886370.0003743156
    7050.00460140570.00252741570.0003061308
    7100.0034787380.00225596770.0002379459
    7150.00270671910.00188138620.0001991565
    7200.00206322270.0014951130.0001695896
    7250.00158316760.00116520610.0001475169
    7300.00110311250.00083529910.0001254442
    7350.00105855770.00090298110.000153442
    7400.00098759330.00094875910.0001824757
    7450.00087701460.00096168140.0002130633
    7500.00076643590.00097460360.0002436509
    7550.00074853760.00096922370.0002245825
    760———
    765———
    770———
    775———
    780———
    785———
    790———
    795———
    800———
    805———
    810———
    815———
    820———
    825———
    830———
    835———
    840———
    845———
    850———
    855———
    860———
    865———
    870———
    875———
    880———
    885———
    890———
    895———
    900———
    905———
    910———
    915———
    920———
    925———
    930———
    935———
    940———
    945———
    950———
    955———
    960———
    965———
    970———
    975———
    980———
    985———
    990———
    995———
    1000———
    1005———
    1010———
    1015———
    1020———
    1025———
    1030———
    1035———
    1040———
    1045———
    1050———
  2. prf-solomatov-pred-olympus-e-m1-mark-ii-b4ccb43e3951 (revision 1)

    Raw samples for prf-solomatov-pred-olympus-e-m1-mark-ii-b4ccb43e3951 (revision 1): R/G/B response at native wavelengths.
    λ (nm)RGB
    4000.00316323460.00504726170.012484581
    4100.0063751920.0083457170.029265624
    4200.00780952260.0158166590.068484254
    4300.0000435520050.0244174170.117007844
    4400.0037954780.0344984350.15139094
    4500.007962480.0441189040.1749234
    4600.0137229130.0591397020.19259685
    4700.0178317430.0871522650.19634604
    4800.0248504230.121082690.18759984
    4900.0244455950.1545620.16558215
    5000.0222542620.192502380.13321012
    5100.0209401040.234211340.100468196
    5200.018668630.262490870.070460804
    5300.011983030.271411240.048900846
    5400.0040789810.264856850.038280305
    5500.00161188980.2476110.030222096
    5600.0185066370.221501480.026147308
    5700.0883322060.183966650.023347694
    5800.171318870.142693770.020450208
    5900.201979040.103607630.01467792
    6000.190807060.071555210.007890827
    6100.171065080.0471208320.002896599
    6200.145486580.0328137280.00016478766
    6300.122681320.0232278310.00010702487
    6400.102104940.0161103980.0000046676996
    6500.080918690.009950610.0000012896369
    6600.06036830.00747480430.0000015745702
    6700.03907880.00414001660.00014940978
    6800.0211961420.00244090660.0000079847805
    6900.0093953170.00251820470.000015481652
    7000.00668962530.00140006070.000093999755