Phase One IQ250

Response

Native RGB responseestimatedPhase One IQ250 · Solomatov GT collection
Hover or tap graph for values
  • red (R)
  • green (G)
  • blue (B)

Astro mode

Emission-line overlay on the active single-profile plot. Values are the source's own native samples (or a labelled linear interpolation).

About this spectrum5 notes
  • Warning: Response scope is unknown; do not interpret this response as a bare-sensor measurement. Dataset interpretation
  • Warning: Physical configuration is not documented; the response cannot be assigned to a confirmed optical configuration. Dataset interpretation
  • Warning: Estimated response; not a primary measurement. Sources and attribution
  • Warning: Normalization is unknown; amplitude comparisons are not established. Dataset interpretation
  • Warning: Uncertainty is not documented. Missing uncertainty does not mean zero uncertainty. Dataset interpretation
Source & details
Source category: estimated
Estimated response: not a primary measurement (e.g. diffraction-grating closed-form recovery, model prediction). Independent of profile_type and quality/confidence grades.
Type: estimated
Estimated response, not a direct measurement; quality and confidence are assessed separately.
Quality: unassessed
Quality has not been assessed; no grade is inferred. Canonical release: no per-leaf scientific-quality assessment is asserted; the source-side claim is preserved verbatim.
Confidence: unassessed
Confidence has not been assessed; no confidence level is inferred. Canonical release: no claim about the per-leaf measurement precision is asserted; the upstream 'as is' wording (where present) is preserved.
Author
Solomatov
Source
Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera' (link)
Source category
estimated (estimated response; not a primary measurement)
Methodology
Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera' — model output.
As-is
Samples rendered verbatim: no smoothing, no interpolation, no zero-padding, no gap bridging in the browser. Documented null sparse cells render as visible gaps.
Optical configuration
cfg-prf-solomatov-pred-phase-one-iq250-52576c6fe4a1 (unknown) — unknown
Normalisation
unknown (original: unknown)
Response unit / scale
unknown / unknown
Sample count
31 samples from 400–700 nm, Δ 10 nm
Profile ID
prf-solomatov-pred-phase-one-iq250-52576c6fe4a1@1
Profile checksum
sha256:dfd31842a6a4248f…
Processing
source_column=predicted-Phase-One-IQ250.csv
Scientific notes
Canonical release: native grid and native R/G/B samples are preserved verbatim; sparse cells (wavelengths absent in the upstream CSV / JSON) are preserved as null; the parser never invents a value.
Citation
Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.
Known limitations
  • source_category=estimated
  • permission_status is 'unknown' on the canonical License record (no independent operational clearance granted).

Graph tools

Inspect, zoom, export, and share the current chart. Native samples only — no interpolation, no averaging.

Channels
Zoom (nm)
Data details
Dataset version
recovered-2026-09-29-all-available-with-ie-202404
Manifest digest
8f960e18d6c9dbef…
Manifest schema
0.1.0-draft
Release kind
full
Linked profiles / sessions
1 profile revision
Raw samples (R/G/B at native wavelengths)
  1. prf-solomatov-pred-phase-one-iq250-52576c6fe4a1 (revision 1)

    Raw samples for prf-solomatov-pred-phase-one-iq250-52576c6fe4a1 (revision 1): R/G/B response at native wavelengths.
    λ (nm)RGB
    4000.00304827650.0049702710.011530922
    4100.00559194060.00754338040.030043917
    4200.0045379030.0143043680.07129556
    4300.000229400290.0227148160.12321632
    4400.0000187556020.0312890820.1565112
    4500.00050688980.039751710.1756172
    4600.000787185040.0548910830.18856433
    4700.0045470360.0840060340.18539616
    4800.016239960.12114120.16859066
    4900.0184437990.15735480.14116065
    5000.0204450540.197596820.10922745
    5100.0257581920.241740630.08198882
    5200.032747870.271060850.061128248
    5300.035593860.27816290.050558418
    5400.0347427580.268880930.049244456
    5500.038954390.247286890.049535
    5600.0553139630.21640420.050138097
    5700.111110030.180622850.044206496
    5800.183190960.14361130.033806365
    5900.208170790.102655460.025470847
    6000.19152010.061655260.022286983
    6100.166668280.0324793640.017888961
    6200.139725340.018856530.012658721
    6300.1158271360.0149182110.0063968594
    6400.096551760.0143280290.0010982925
    6500.074465190.0143485970.000021770269
    6600.0566356740.0168217530.00003508527
    6700.0363839270.0116125730.0000062206072
    6800.0191824080.0064835950.000009260912
    6900.0082080660.00430745350.000025454356
    7000.0047250580.00283651640.00041971784