Sony Xperia 1 III Wide angle Camera

Response

Native RGB responseestimatedSony Xperia 1 III Wide angle Camera · Solomatov GT collection
Hover or tap graph for values
  • red (R)
  • green (G)
  • blue (B)

Astro mode

Emission-line overlay on the active single-profile plot. Values are the source's own native samples (or a labelled linear interpolation).

About this spectrum5 notes
  • Warning: Response scope is unknown; do not interpret this response as a bare-sensor measurement. Dataset interpretation
  • Warning: Physical configuration is not documented; the response cannot be assigned to a confirmed optical configuration. Dataset interpretation
  • Warning: Estimated response; not a primary measurement. Sources and attribution
  • Warning: Normalization is unknown; amplitude comparisons are not established. Dataset interpretation
  • Warning: Uncertainty is not documented. Missing uncertainty does not mean zero uncertainty. Dataset interpretation
Source & details
Source category: estimated
Estimated response: not a primary measurement (e.g. diffraction-grating closed-form recovery, model prediction). Independent of profile_type and quality/confidence grades.
Type: estimated
Estimated response, not a direct measurement; quality and confidence are assessed separately.
Quality: unassessed
Quality has not been assessed; no grade is inferred. Canonical release: no per-leaf scientific-quality assessment is asserted; the source-side claim is preserved verbatim.
Confidence: unassessed
Confidence has not been assessed; no confidence level is inferred. Canonical release: no claim about the per-leaf measurement precision is asserted; the upstream 'as is' wording (where present) is preserved.
Author
Solomatov
Source
Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera' (link)
Source category
estimated (estimated response; not a primary measurement)
Methodology
Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera' — model output.
As-is
Samples rendered verbatim: no smoothing, no interpolation, no zero-padding, no gap bridging in the browser. Documented null sparse cells render as visible gaps.
Optical configuration
cfg-prf-solomatov-pred-sony-xperia-1-iii-wide-angle-camera-e5fd6897b410 (unknown) — unknown
Normalisation
unknown (original: unknown)
Response unit / scale
unknown / unknown
Sample count
31 samples from 400–700 nm, Δ 10 nm
Profile ID
prf-solomatov-pred-sony-xperia-1-iii-wide-angle-camera-e5fd6897b410@1
Profile checksum
sha256:90a83ec017b626e7…
Processing
source_column=predicted-Sony-Xperia-1-III-Wide-angle-Camera.csv
Scientific notes
Canonical release: native grid and native R/G/B samples are preserved verbatim; sparse cells (wavelengths absent in the upstream CSV / JSON) are preserved as null; the parser never invents a value.
Citation
Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.
Known limitations
  • source_category=estimated
  • permission_status is 'unknown' on the canonical License record (no independent operational clearance granted).

Graph tools

Inspect, zoom, export, and share the current chart. Native samples only — no interpolation, no averaging.

Channels
Zoom (nm)
Data details
Dataset version
recovered-2026-09-29-all-available-with-ie-202404
Manifest digest
8f960e18d6c9dbef…
Manifest schema
0.1.0-draft
Release kind
full
Linked profiles / sessions
1 profile revision
Raw samples (R/G/B at native wavelengths)
  1. prf-solomatov-pred-sony-xperia-1-iii-wide-angle-camera-e5fd6897b410 (revision 1)

    Raw samples for prf-solomatov-pred-sony-xperia-1-iii-wide-angle-camera-e5fd6897b410 (revision 1): R/G/B response at native wavelengths.
    λ (nm)RGB
    4000.003271350.00462644640.011813261
    4100.00543201950.00715311760.029161766
    4200.0041190020.0129207210.07004966
    4300.0000294389170.0198399420.1203953
    4400.0000112924340.0256016720.15346979
    4506.496312e-70.032639010.17380549
    4600.0000197124570.048187230.18657626
    4700.00629133360.0792378040.18375136
    4800.0179909950.11826860.16824344
    4900.0228736920.155494690.14464164
    5000.0231904180.19545770.11344614
    5100.0242457970.238854810.08634723
    5200.0236381870.2663240.06440809
    5300.0177635680.27444060.05007206
    5400.0075986440.26719820.04378302
    5500.0047908260.248348360.038567413
    5600.0153251080.222535130.034616336
    5700.078258110.185591240.03262448
    5800.172366510.143773290.03196824
    5900.211711060.1052428260.025328062
    6000.199668910.07374240.016824817
    6100.178824410.0497956950.00976566
    6200.152473050.0360338870.0051518707
    6300.130725250.025192820.0037900647
    6400.110796430.0166217440.0036214227
    6500.088728060.0101683650.003374517
    6600.06768710.00729251930.0033833606
    6700.0447617880.00342810920.002485226
    6800.0241087470.00193129980.001260898
    6900.0092647460.00264096730.00031816168
    7000.0075048640.00084013240.0006945463